Chapter 4 : IMPRES 2 Batteries and Chargers
4.7
End-of-Service-Life Indication
The IMPRES 2 charger may indicate IMPRES 2 battery end-of-service by alternating red and green
LED upon successful completion of calibration or reconditioning.
When batteries are used, normal wear reduces available capacity. IMPRES 2 chargers compare
IMPRES 2 battery capacity to the battery rated capacity. When the capacity is at a very low value, the
IMPRES 2 battery may be nearing its end-of-service. The IMPRES 2 battery remains usable. In some
scenarios, it may be preferable to deploy the battery to someone who does not require large battery
capacity to complete a work shift.
4.8
Manually Terminating Calibration or Reconditioning
.
When and where to use: To manually terminate calibration or reconditioning, perform the following
steps:
Procedure:
1 Remove the battery from the charger pocket.
2 Within five seconds, reinsert the battery into the charger pocket.
Battery discharge immediately terminates, and normal battery charging starts. The LED indicates
charge status.
4.9
Reconditioning the Switch
When and where to use: The charger is equipped with a switch on the bottom of the unit that can
be utilized to manually terminate the reconditioning process (as a systemic, on-going use-case). The
charger continues to provide an indication that the battery needs to be reconditioned.
Procedure:
To enable the recondition feature, switch the RECONDITION to ON located at the bottom of the
charger.