A window shows the progress of the upgrade until completion.
6 Close the window once all upgrades have been completed.
4.6
Manually Initiating Calibration or Reconditioning
.
When and where to use:
If within 30 minutes that battery is moved to a charger that has calibration enabled, the last charging
state resumes, preventing automatic start of calibration or reconditioning.
Procedure:
1 Insert the battery into the charger pocket.
2 Within 2.5 minutes, remove the battery from the charger pocket.
3 Within five seconds, reinsert the battery into the charger pocket.
Calibration or reconditioning starts immediately, beginning with battery discharge, indicated by steady
amber LED. Calibration or reconditioning is complete only after full charge, indicated by steady green
LED.