Chapter 4 : IMPRES 2 Batteries and Chargers
If the IMPRES 2 battery is removed from one IMPRES 2 charger pocket and, within 30 minutes,
inserted into another or the same IMPRES 2 charger pocket, then charging resumes at the point where
charging was interrupted. This feature prevents battery over-charging and minimizes the loss of cycle
life.
4.4
Automatic IMPRES 2 Battery Calibration or Reconditioning
The IMPRES 2 charger automatically assesses the condition of an IMPRES 2 battery.
Based on this condition, the charger automatically calibrates or reconditions the battery. Interruption
of either the discharge phase or the full charge phase delays calibration until the next charging
opportunity. Calibration or reconditioning may be enabled or disabled using charger setup mode. When
disabled and the IMPRES 2 battery requires calibration or reconditioning, the LED indicates alternating
amber and green at battery insertion and after the battery is charged.
4.5
IMPRES 2 Battery with Self Calibration and Recondition
4.5.1
Updating Firmware
.
Prerequisites: Remove all inserted batteries from target device or charger.
Procedure:
1 Connect the device or charger to your computer using USB.
The connected device or charger is shown on the main window of the MSI Charger
Reprogrammer.
16
CAUTION: IMPRES 2 batteries that has this icon on the battery label
do not require periodic calibration and reconditioning when docked into
this IMPRES 2 charger (with software version V2.03 or newer).
NOTE: Ensure that your charger is always updated with the latest
firmware. The Motorola Solutions Charger Reprogrammer application
package can be downloaded from Motorola Online (MOL) or Motorola
Solutions website.