4.3 How to unlock the operator
WARNING Disconnect the power supply from the control panel before releasing the operator. In case you cannot turn the power
off, you will necessarily have to re-lock the motor in the position in which it was unlocked.
• Turn the cap placed on the back of LOOK in order to discover the underlying shaped hole.
• Insert the release key inside the shaped hole paying attention to the direction of insertion (Pic. 8.a).
• Rotate 90 degrees (counterclockwise to unlock, clockwise to lock) the release key (Pic. 8.b).
WARNING Remember to protect the lock with the respective cover so that the operator is protected by water or powder (even when it
remains unlocked for a long time).
WARNING During this operation gate may perform uncontrolled movements: operate with extra care so to avoid any risk.
4.4 Adjustment of the limit-switches
After the installing, limit switches must be adjusted (only for models that foresee them) as follows (Pic. 9):
WARNING When adjusting the limit switches, take away the little cover of the extrusion using a screwdriver and check the correct
internal microswitches are moving (Pic. 10).
• Unscrew the A fi xing nuts so to operate on C and D screws
• Adjust opening and closing limit switches
• Screw the A fi xing screws by keeping C and D blocked by a screwdriver so to maintain the adjustments.
WARNING While closing the inspection cover, use silicone to seal the leak (Pic. 11).
5 ELECTRICAL CONNECTIONS (Pic. 12)
Run the motor connections following the wiring diagrams.
WARNING For adequate electrical safety, keep low safety voltage wires (controls, electro-locks, antenna, auxiliary power) clearly separate
from 230V ~ power wires (minimum 4 mm in air or 1 mm via supplementary insulation) placing them in plastic raceways and securing
them with adequate clamps near terminal boards.
WARNING For connection to the mains, use a multipolar cable having a minimum section 3x1,5 mm² and complying with the current
regulations. For connecting the motors, use a minimum cross section 1,5 mm² cable and complying with the current regulations. As
an example, if the cable is out side (outdoor), must be at least equal to H05RN-F, whereas if it (in a raceway), must be at least equal to
H05VV-F.
WARNING Connect to the power supply 230-240 V ~ 50/60 Hz through a multi pole switch or a different device that can ensure multi
pole disconnection from the power supply, with a contact opening of 3 mm.
WARNING All wires must be striped and unsheathed in the immediate vicinity of terminals. Keep wires slightly longer to subsequently
eliminate any excess.
WARNING Maintain the ground conductor at a major length respect the active conductors so that, if the cable exit from its fi xing housing,
the active conductors tighten up as fi rst.
WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,75mm
Program the control board to complete all adjustments. It is now possible to supply a complete installation in compliance with all stan-
dards required for gate automation. See the instructions provided with the control panel to be connected.
Finally, verify that all adjustments operations have been correctly performed and that safety devices and unlocking device properly
work.