OPERATION
NOTE: Read Operator's Manual carefully before operating this unit.
Be certain to block the wheels to prevent the unit from moving
while operating. Always make sure the unit is level and properly
grounded. Check engine oil before starting.
1. Turn the idle control switch to the OFF position. (See Fig. 3)
2. Move choke lever to full choke. If re-starting a warm engine, the choke
should be left in the off position. (See Fig. 4)
3. Turn the key to the START position, hold until engine starts.
4. When the engine starts, release key, allowing it to return to the ON
position.
NOTE: Do not crank the engine continuously for more than 30 sec-
onds at a time. If the engine does not start, allow for a 3 minute
cool down period between starting attempts. Failure to follow
these guidelines can damage the starter motor.
If the starter does not turn the engine over, shut offthe starter
immediately. Do not make further attempts to start the engine
until the condition is corrected. Do not jump start using another
battery.
5. Slowly move choke lever to no choke.
6. Allow unit to run two (2) minutes to warm-up.
7. Test the GFCI receptacle(s) on the unit. Push the test button. The reset
button should pop out and there should be no power at the receptacle.
Apply a test load or lamp to each receptacle to verify. IF THE RESET
BUTTON DOES NOT POP OUT, DO NOT USE THE RECEPTACLES(S).
SEE DEALER FOR SERVICE IMMEDIATELY.
8. If GFCI receptacle(s) test correctly, firmly push the reset button to restore
power. A distinctive click should be heard or felt when this is complete.
IF THE RECEPTACLE(S) DO NOT RESET PROPERLY, DO NOT USE
THE RECEPTACLE(S). SEE DEALER FOR SERVICE IMMEDIATELY.
9. Turn idle control switch to ON position. Loads can now be applied to
unit.
NOTE: This engine is equipped with a "Low Oil" shutdown system
for engine protection. The engine stops when the oil level gets
too low. The engine will not restart without adding oil. Refer to
Preparing the Generator; Engine Fuel Capacity for instructions
on adding oil.
SHUTDOWN
1. Remove all load by turning off electrical appliances and unplugging
electric cords.
2. Allow engine to run at idle speed to cool for two (2) minutes.
NOTE: Failure to allow the engine to cool at idle for two (2) minutes
may result in damage to the generator.
3. Turn the engine key to the OFF position.
CONTROLS
OIL WARNING DEVICE:
NOTE: This engine is equipped with a "Low Oil" shutdown system
for engine protection. The engine stops when the oil level gets
too low. The engine will not restart without adding oil. If the unit
is tilted too much during operation, it may suddenly stop even
though the oil level is not low.