OPERATION INSTRUCTIONS
cleanouts located inside the firebox, one on each side
of the burnpot. The clean outs are secured to the firebox
with (2) 5/16" screws each. Remove the clean outs
and vacuum out any accumulated ash. This should be
done at least once per month or more frequently if large
amounts of ash are noticed while cleaning or if the stove
does not seem to be burning properly.
Over time ash or dust may accumulate on the blades of the
circulation & exhaust fans. The fans should be inspected,
periodically, and if any accumulation is present vacuumed
clean as the ash or dust can impede the fans performance.
It is also possible that creosote may accumulate in the
exhaust fan therefore, this must be brushed clean. The
exhaust fan can be found behind the left side panel (facing
the front of the heater), the circulation fan can be found
behind the right side panel. To access the igniter, remove
the air inlet tube and cover (2 screws). The auger motor is
located in the center rear of the unit. Note: When cleaning,
take care not to damage the fan blades.
If a vacuum is used to clean your stove, we suggest
using the AV15E AshVac vacuum. The AV15E AshVac is
designed for ash removal. Some regular vacuum cleaner
(i.e. shop vacs) may leak ash into the room.
DO NOT VACUUM HOT ASH.
FAILURE TO PROPERLY MAINTENANCE THE CLEAN
OUTS WILL RESULT IN POOR PERFORMANCE OF THIS
Clean-Out Plates
17
© 2024 United States Stove Company
WARNING:
STOVE.