Télécharger Imprimer la page

United States Stove Company VOGELZANG VG5722-W Manuel D'instructions Et D'utilisation Du Propriétaire page 16

Publicité

IF STOVE RUNS OUT OF PELLETS
This stove is fitted with a fuel level sensor that, when
connected to WiFi and detects a low fuel level, will cause
the display on the stove to flash and send a notification to
the accompanying app.
FUEL LEVEL
SENSOR
The fire goes out and the auger motor and blowers will
run until the stove cools. This will take 30 minutes or
longer depending on the heat remaining in the appliance.
After the stove components stop running all lights on
the display will go out and the two digit display will begin
showing "E3".
REFUELLING
WARNING:
• KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT
WHEN REFILLING.
• DO NOT OVERFILL HOPPER.
CAUTION:
• THE HOPPER AND STOVE TOP WILL BE HOT
DURING OPERATION; THEREFORE, YOU SHOULD
ALWAYS USE SOME TYPE OF HAND PROTECTION
WHEN REFUELING YOUR STOVE.
• DO NOT TOUCH THE HOT SURFACES OF THE STOVE.
EDUCATE ALL CHILDREN ON THE DANGERS OF A
HIGH-TEMPERATURE STOVE. YOUNG CHILDREN
SHOULD BE SUPERVISED WHEN THEY ARE IN THE
SAME ROOM AS THE STOVE.
• NEVER PLACE YOUR HAND NEAR THE AUGER
WHILE THE STOVE IS IN OPERATION.
• WE RECOMMEND THAT YOU NOT LET THE HOPPER
DROP BELOW 1/4 FULL.
© 2024 United States Stove Company
OPERATION INSTRUCTIONS
TAMPER WARNING
This wood heater has a manufacturer-set minimum low
burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this
wood heater in a manner inconsistent with operating
instructions in this manual.
SHUTDOWN PROCEDURE
NEVER SHUT DOWN THIS UNIT BY UNPLUGGING IT
FROM THE POWER SOURCE.
Turning your stove off is a matter of pressing the "POWER"
button on the display board. The auger motor will stop,
and the blowers will continue to operate until the internal
firebox temperatures have fallen to a preset level.
1. Your stove is equipped with a high temperature
thermodisc. This unit has a manual reset thermodisc.
This safety switch has two functions.
A. To recognize an overheat situation in the stove and
shut down the fuel feed or auger system.
B. In case of a malfunctioning convection blower, the
high-temperature thermodisc will automatically shut
down the auger, preventing the stove from overheating.
NOTE: On some units, once tripped, like a circuit breaker,
the reset button will have to be pushed before restarting
your stove. On other units the thermodisc has no reset
button and will reset itself once the stove has cooled. The
manufacturer recommends that you call your dealer if this
occurs as this may indicate a more serious problem. A
service call may be required.
2. If the combustion blower fails, an air pressure switch
will automatically shut down the auger.
NOTE: Opening the stove door for more than 30 seconds
during operation will cause enough pressure change to
activate the air switch, shutting the fuel feed off. The stove
will shut down and show "E2" on the two digit display. The
stove has to fully shut down before restarting.
INTERIOR CHAMBERS
• Burn Pot - Periodically remove and clean the burn pot
and the area inside the burn pot housing. In particular,
it is advisable to clean out the holes in the burn pot to
remove any build up that may prevent air from moving
through the burn pot freely.
• Heat Exchanger - There are two clean out plates that
need to be removed in order to clean the fly ash out
of the heat exchanger. Open the door to access the
16
WARNING:

Publicité

loading