Liens rapides

Owner's Instruction and Operation Manual
Model Number:
VG5722-W
Report #: F22-782
Certified to ASTM E1509-2022 and CAN/ULC
S627:2023; Complies to CAN ICES-3(B)/NMB-3(B);
Contains IC:23243-WBR1DIPEX
Mobile Home / Transportable Building Approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For
your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or fire officials about
permits, restrictions and installation requirements in your area. NEVER OPERATE THIS
PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
© 2024 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals
including carbon monoxide, which is known to the
State of California to cause cancer, birth defects,
and/or other reproductive harm. For more
information, go to
854003F-1904N
www.P65warnings.ca.gov
Ph. 800-750-2723

Publicité

loading

Sommaire des Matières pour United States Stove Company VOGELZANG VG5722-W

  • Page 1 State of California to cause cancer, birth defects, and/or other reproductive harm. For more emissions standards. information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2024 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 2 Your pellet stove has been safety tested and listed to ASTM E1509-2022 and CAN/ULC S627:2023. This manual describes the installation and operation of the Vogelzang VG5722-W pellet stove. This heater meets the 2020 U.S. Environmental Protection Agency’s emission limits for wood-heaters sold after May 15, 2020. Under specific EPA test conditions burning wood pellet fuel this heater has been shown to deliver heat at a rate of 13,640 to 32,591 Btu/hr.
  • Page 3 Declaration of Completion: As the qualified person responsible for the work described above, I confirm that the appliance as associated work has been installed as per manufacturer’s instructions and following any applicable building and installation codes. Signed: _______________________________________ Print Name: ___________________________________ Date: _______________ Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE © 2024 United States Stove Company...
  • Page 4 5 Pin Main Wiring Harness. Connect the 4 Pin Wiring Harness to the bottom left-hand corner of the control panel. 5 Pin Main Wiring Harness 4 Pin Fuel Sensor 7 Pin Com Cable © 2024 United States Stove Company...
  • Page 5 2. Next slide the wood handle onto the door handle rod. 3. Slide the other provided washer onto the door handle rod. 4. Screw the provided nut onto the end of the door handle rod to secure everything in place. © 2024 United States Stove Company...
  • Page 6 OR PINCH THE CORD UNDER FURNITURE. WETT (Canada) technician. To find the nearest qualified installer, go to: CAUTION: https://nficertified.org, BURNING FUEL CREATES CARBON MONOXIDE AND https://www.wettinc.ca/ CAN BE HAZARDOUS TO YOUR HEALTH IF NOT PROPERLY VENTED. © 2024 United States Stove Company...
  • Page 7 A Floor Protector of 1” (26 mm) thick is recommended for this installation. Canada - Floor protector must comply with CAN/ULC standards. Must extend 18” (458mm) past the front and 8” (203mm) beyond each side of unit. © 2024 United States Stove Company...
  • Page 8 Use the designated holes to secure the unit to the floor. venting installation of this unit. Purchase the appropriate appliance adapter from your preferred venting company prior to starting the ventilation process. Exhaust Pipe Fresh Air Intake © 2024 United States Stove Company...
  • Page 9 An uncontrollable burn or excessive temperature indicates excessive draft. Take into account the chimney’s location to ensure it is not too close to neighbours or in a valley which may cause unhealthy or nuisance conditions. © 2024 United States Stove Company...
  • Page 10 Once you have located the center point, To get the most efficient use of re-circulated heat, you on the interior wall, cut a 7” (175 mm) diameter hole should consider a room that is centrally located within through the wall. © 2024 United States Stove Company...
  • Page 11 (3.7m), the pellet vent pipe size should be increased to the termination cap or one every 4ft (1.22m) to make the 4” (102 mm) in diameter. system more stable. If you live in an area that has heavy © 2024 United States Stove Company...
  • Page 12 860001, 3-6” transition into 6” connector pipe (the illustration is only an example). Please conform to any local building codes or regulations having jurisdiction before you have a qualified installer proceed with this installation. © 2024 United States Stove Company...
  • Page 13 The ON/OFF HEAT MODE fuel feed system will stop pulling fuel from the hopper and, once the fire goes out and the heater cools down, (POWER) RANGE the fans will stop running. © 2024 United States Stove Company...
  • Page 14 BEGIN TO MOVE AT ANY TIME WHILE THE STOVE Your pellet stove is designed to burn premium hardwood IS PLUGGED IN. pellets that comply with the Pellet Fuels Institute (PFI) standard (minimum of 40 lbs density per cubic ft, 1/4” to © 2024 United States Stove Company...
  • Page 15 ROOM AIR FAN When starting your stove the Room Air Fan will not come on until the stove’s heat exchanger warms up. This usually takes about 10 minutes from start-up. © 2024 United States Stove Company...
  • Page 16 • WE RECOMMEND THAT YOU NOT LET THE HOPPER need to be removed in order to clean the fly ash out DROP BELOW 1/4 FULL. of the heat exchanger. Open the door to access the © 2024 United States Stove Company...
  • Page 17 If a vacuum is used to clean your stove, we suggest using the AV15E AshVac vacuum. The AV15E AshVac is designed for ash removal. Some regular vacuum cleaner (i.e. shop vacs) may leak ash into the room. DO NOT VACUUM HOT ASH. © 2024 United States Stove Company...
  • Page 18 • Enter the 6 digit verification code that was sent to the previously entered email address. • Provide access to the two permissions requested. • Allow notifications through the phones settings. • The app is ready to add the unit. © 2024 United States Stove Company...
  • Page 19 The app and unit are now ready for use. Device Select Device Name & Screen Device Sharing Settings Current Room Temperature Temperature Adjuster Stove Setting Decrease Increase Temperature Temperature Setpoint Setpoint Mode Power ON/OFF Heat Range © 2024 United States Stove Company...
  • Page 20 Check the hopper periodically to determine if there is any entire system be professionally inspected, cleaned and, if sawdust (fines) that is building up in the feed system or © 2024 United States Stove Company...
  • Page 21 5. Re-install the retainer and eight nuts and rope gasket Gaskets Inspected using high-temperature silicone to adhere the gasket Glass Wiped Cleaned to the door. Hopper (end of Empty & 6. Never use substitute materials for the glass. season) Vacuumed © 2024 United States Stove Company...
  • Page 22 DO NOT INSTALL IN AN ALCOVE 200 mm (8 in) beyond the appliance on other sides, shall DO NOT INSTALL IN ANY FIREPLACE be protected by a continuous, durable, non-combustible © 2024 United States Stove Company...
  • Page 23 If the other items check out OK, replace the high limit switch. ATTENTION: THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL. © 2024 United States Stove Company...
  • Page 24 If you hear a click, the air switch is working. BE CAREFUL TOO MUCH VACUUM CAN DAMAGE THE AIR SWITCH. © 2024 United States Stove Company...
  • Page 25 The control board is not sending power to the POF There should be a 5-volt (approximately) current going to the POF thermodisc or other auger system components. thermodisc after the stove has been on for 10 minutes. © 2024 United States Stove Company...
  • Page 26 If the sensor is not unplugged then turned on the sensor is damaged or has a short. If the sensor is damaged or has a short it will need to be replaced. © 2024 United States Stove Company...
  • Page 27 Circuit board malfunction. is fine. If there is NOT power being sent to the blower when it shuts off during operation, then you have a bad control board. © 2024 United States Stove Company...
  • Page 28 If there is not a full current going to the auger motor when the fuel feed light is on, you have a bad control board. © 2024 United States Stove Company...
  • Page 29 Bad Pellets. (Applies to GLASS “SOOT’S” UP AT A You might also want to try a brand that is made from a different VERY FAST RATE Only) type of wood (softwood vs. hardwood). Different woods have different characteristics when being burned. © 2024 United States Stove Company...
  • Page 30                 ENSURE THE WIRES ARE CONNECTED TO THE BOTTOM TWO PRONGS OF THE HOPPER SWITCH AS SHOWN. CORRECT WRONG © 2024 United States Stove Company...
  • Page 31 Drive Motor 80866 (1.5 RPM CCW) IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING USSC PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM USSC. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2024 United States Stove Company...
  • Page 32 Engineer Name: _____________________________________ Engineer Name: _____________________________________ License No.: ________________________________________ License No.: ________________________________________ Company: ___________________________________________ Company: ___________________________________________ Telephone No.: ______________________________________ Telephone No.: ______________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced: _____________________________________ Items Replaced: _____________________________________ © 2024 United States Stove Company...