OPERATION INSTRUCTIONS
PRE-START-UP CHECK
Remove burn pot, making sure it is clean and none of the
air holes are plugged. Clean the firebox, and then reinstall
burn pot. Clean door glass if necessary (a dry cloth or
paper towel is usually sufficient). Never use abrasive
cleaners on the glass or door. Check fuel in the hopper,
and refill if necessary.
BUILDING A FIRE
Never use a grate or other means of supporting the fuel.
Use only the burn pot supplied with this heater. Hopper lid
must be closed in order for the unit to feed pellets. During
the start-up period:
• Make sure the burn pot is free of pellets.
• DO NOT open the viewing door.
• DO NOT add pellets to the burn pot by hand.
NOTE: During the first few fires, your stove will emit an odor
as the high-temperature paint cures or becomes seasoned
to the metal. Maintaining smaller fires will minimize this.
Avoid placing items on the stovetop during this period
because the paint could be affected. Attempts to achieve
heat output rates that exceed heater design specifications
can result in permanent damage to the heater.
OPTIMAL OPERATION
This pellet stove has been certified by the US EPA to
meet strict 2020 guidelines. To Insure this unit produces
the optimal minimal emissions, it is critical to follow
the following guidelines. To achieve a "high burn" your
stove should be set on setting 5 with the damper open.
To achieve a "medium burn" your stove should be set on
setting 3 with the damper 50% open. To achieve a "low
burn" your stove should be set on setting 1with the damper
closed. If the door is opened while the stove is in operation
it must be closed within 30 seconds or the stove will shut
down. If the stove shuts down push the "On/Off" button to
re-start your stove. The stove will have to fully shut down
and turn off before you will be able to restart the stove.
DAMPER SETTINGS
Fully Open
Fully Closed
IGNITOR
1. Fill the hopper and clean the burn pot.
2. Press the "On/Off" button.
3. Set the heat range/temperature. Manual Mode - Press
the "Display Button" to see the current heat range. Use
the up and down arrows to adjust the heat range.
T-stat Mode - Press the "Display Button" to see the
current temperature setting. Use the up and down
arrows to adjust the temperature as needed.
If the fire doesn't start in 12 minutes, press "On/Off", wait
a few minutes, clear the burn pot, and start the procedure
again.
OPENING DOOR
• DO NOT OPERATE YOUR STOVE WITH THE VIEWING
DOOR OPEN. THE AUGER WILL NOT FEED PELLETS
UNDER THESE CIRCUMSTANCES AND A SAFETY
CONCERN MAY ARISE FROM SPARKS OR FUMES
ENTERING THE ROOM.
• THE DOOR MUST BE CLOSED AND SEALED DURING
OPERATION.
If the door is opened while the stove is in operation it must
be closed within 30 seconds or the stove will shut down. If
the stove shuts down push the "On/Off" button to re-start
your stove. The stove will have to fully shut down and turn
off before you will be able to restart the stove.
ROOM AIR FAN
When starting your stove the Room Air Fan will not come
on until the stove's heat exchanger warms up. This usually
takes about 10 minutes from start-up.
15