Note:
When powered up, the unit performs a self-check (including one panning, tilting, zooming and
focusing operation).
• 24 V AC Power Supply Connection
Recommended wire gauge sizes for 24 V AC line.
Copper wire size
(AWG)
#24
(0.22mm2)
#22
(0.33mm2)
#20
(0.52mm2)
#18
(0.83mm2)
Length
of cable
(approx.)
(m)
20
30
45
75
(ft)
65
100
160
260
Accessory Connector Information
Prepare the individual conductors for clamping.
Use MOLEX band tool part number 57027-5000
(for UC-Style Cable UL1015) or 57026-5000 (for
UL-Style UL1007) for clamping the contacts.
After clamping the contacts, push them into the
proper holes in the accessory connector of this
camera until they snap in place.
Pin no.
Power source
1
24 V AC LIVE
2
24 VAC NEUTRAL
3
Ground
4
Not use
4
3
2
1
Up
t
Wire
<= i_ ~_r*fn
Contact
How to Assemble the Cable with the
Accessory Connector
Strip back the cable jacket approx. 3 mm (0.1
inch) and separate the individual conductors.
Approx.
3 mm (0.1 inch)
yyjre
Contact
\
3
Up
4V
|
^ Insert
f-rn/U
—
vJ |
Insert the wire until A position
———t ancj C|amp the contacts.
r CAUTIONS-
• Shrinking the cable-entry seal is a one¬
time procedure. Do not shrink the cable-
entry seal until it has been ascertained
that the unit is functioning.
CONNECT THIS TO 24 V AC CLASS 2
POWER SUPPLY ONLY.
• To prevent fire or electric shock hazard,
use a UL listed cable (VW-1, style 1007)
should be used for the cable for the 24 V
AC Input Terminals.