QUICK REPAIRS
Only an authorized technician may work on electrical repairs on this appliance.
Bradley Technologies Canada Inc. accepts no responsibility for any malfunction or damage which is
caused by unsuitable electrical repairs.
Cabinet sensor and temperature high limit switch removal
When the smoker detects the sensor failure or loses the connection, the error code will
be displayed with audible alarm. Press the rotary dial to cancel the alarm. Check the
sensor and its connections.
To change sensor in the cabinet, follow these steps:
1. Turn off the power switch. See the Switch (9) location on page 7.
2. Disconnect the power cable from the electrical outlet.
3. Ensure adequate time to cool down the smoker after use.
4. Remove all racks from the smoker.
5. Remove 4 phillips screws holding down the sensor cover plate. See #11 at page 7.
6. Remove the cover and the piece of insulation covering the sensor.
7. Disconnect the sensor wire connector (1).
8. Remove the phillips screw (2) from inside the cabinet holding the sensor and replace the sensor.
9. High temperature limit switch (3) is
located just below the temperature
sensor.
10. It can be reset by pressing on the middle
knob on the switch itself (4).
11. To replace the switch, disconnect the wire
leads (5) on either side of the switch and
remove the 2 phillips screws (6).
25 |
P a g e