Télécharger Imprimer la page
Delta TECK II 81T2 Serie Guide D'entretien Et D'installation
Delta TECK II 81T2 Serie Guide D'entretien Et D'installation

Delta TECK II 81T2 Serie Guide D'entretien Et D'installation

Flush valves
Masquer les pouces Voir aussi pour TECK II 81T2 Serie:

Publicité

Liens rapides

Electronic Exposed TECK
(with Wallmount
Soupapes de chasse d'eau électroniques TECK
exposées (avec
RECORD MODEL NUMBER:
INSCRIRE LE NUMÉRO DE MODÈLE
81T2 __ 1 __ __ __ - WMSHWA
VALVE TYPE
0 = W/C (Water Closet)
3 = Urinal
TYPE DE
SOUPAPE
0 = W/C (toilettes)
3 = Urinoir
NOTICE
Not all options are available on all base models
AVIS
Les options ne sont pas toutes disponibles sur tous les modèles de base
81T201-WMSHWA
PLEASE LEAVE the Maintenance & Installation (M&I) manual with owner for maintenance and troubleshooting information.
VEUILLEZ LAISSER le Guide d'entretien et d'installation au propriétaire pour les informations d'entretien et de dépannage.
II Flush Valves
®
)
mural )
ADDITIONAL OPTIONS
(leave blank if not applicable)
1 = V/B Tube w/Tee Assembly (W/C only)
OPTIONS ADDITIONNELLES
(laisser en blanc si non applicable)
1 = Tuyau V/B avec/ensemble en T (toilette
seulement)
II
MD
AVAILABLE FLUSH VOLUMES
Blank = Adjustable
42 = 1.1 gpf (4.2 Lpf) fixed flush (W/C only)
48 = 1.27 gpf (4.8 Lpf) fixed flush (W/C only)
05 = 0.125 gpf (0.5 Lpf) fixed flush (Urinal only)
19 = 0.5 gal (1.9 Lpf) fixed flush (Urinal only)
DISPONIBLES VOLUMES DE CHASSE
Blanc = Réglable
42 = Chasse fixe de 1,1 gal./chasse (4,2 L/chasse) (toilette seulement)
48 = Chasse fixe de 1,27 gal./chasse (4,8 L/chasse) (toilette seulement)
05 = Chasse fixe de 0,125 gal./chasse (0,5 L/chasse) (urinoir seulement)
19 = Chasse fixe de 0,5 gal./chasse (1,9 L/chasse) (urinoir seulement)
81T231-WMSHWA
216040, Rev. C

Publicité

loading

Sommaire des Matières pour Delta TECK II 81T2 Serie

  • Page 1 Electronic Exposed TECK II Flush Valves ® (with Wallmount Soupapes de chasse d’eau électroniques TECK exposées (avec mural ) RECORD MODEL NUMBER: INSCRIRE LE NUMÉRO DE MODÈLE 81T2 __ 1 __ __ __ - WMSHWA VALVE TYPE ADDITIONAL OPTIONS AVAILABLE FLUSH VOLUMES 0 = W/C (Water Closet) (leave blank if not applicable) Blank = Adjustable...
  • Page 2 Table of Contents Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Dimensional Table (see Figure 1) .
  • Page 3 Table des matières Données techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Tableau des dimensions (voir Figure 1) .
  • Page 4 TECHNICAL DATA DONNÉES TECHNIQUES NOTICE Flushometer MUST be paired with a fixture of equivalent flush volume. La soupape de chasse DOIT être utilisée avec un dispositif de chasse d’eau de débit équivalent. AVIS DIMENSIONAL TABLE (see Figure 1) Figure 1 TABLEAU DES DIMENSIONS (voir Figure 1) Models Tolerance...
  • Page 5 INSTALLATION INSTALLATION Step 1. SUppLY StOp INStALLAtION (see Figure 2) Figure 2 WARNING It is important to FLUSH and thoroughly CLEAN water lines to 1.0” ELIMINATE contaminants (example - scale, sediment, gravel, cuttings, (25mm) solder, etc.). 1. Cut the end of the 1.0” (25mm) copper inlet tube (SO1 ) so that it is 1.0”...
  • Page 6 Step 3. FLUSHOMeteR SIZING (see Figure 4) Figure 4 1. Assemble vacuum breaker components (G) into the outlet tube (I). 2. Attach the outlet tube (I) and vacuum breaker components (G) onto the flushometer body (F) secure with the coupling nut (H). 3.
  • Page 7 Step 5. IF LeFt HAND StOp IS ReQUIReD (see Figure 6) Figure 6 1. Remove the cover (F-4) by taking out the two cover screws (F-3). Left Hand Inlet Right Hand Inlet 2. You will now see the cover gasket (F-5). DO NOT remove the four screws (F-7) that hold down the cap/ WARNING solenoid assembly (F-6).
  • Page 8 Step 7. JUNCtION BOX INStALLAtION (see Figure 8) Figure 8 1. Install the plastic bushing (O) into the hole on the cover-plate (P). 2. Remove screws (F-3) and cover (F-4) from the flushometer body (F) 3. Measure the distance (cc) from the back of the gasket (F-5) to the front of the electrical box (E).
  • Page 9 Step 8. SeNSOR BOX INStALLAtION (see Figure 9) 1. Securely the 4" x 4" (102 x 102 mm) sensor box (S) to the wall structure as outlined in Figure 8. ÉtApe 8. INStALLAtION DU BOÎtIeR DU CApteUR (voir Figure 9) 1.
  • Page 10 Step 9. pOWeR AND SeNSOR CONNeCtIONS (see Figure 10) Figure 10 WARNING Verify the power is “OFF” going to the CSA and/or UL approved Class 2 - 24VAC transformer. 1. Attached supplied plasterguard (T) onto the sensor box (S), using screws (T-1) provided.
  • Page 11 FLUSH VOLUME ADJUSTMENT RÉGLAGE DU VOLUME DE CHASSE ADJUSTABLE MODELS (listed below) FIXED NON-ADJUSTABLE MODELS (listed below) The Regulating Screw (F-15) may be adjusted according to job conditions The Flushometer CANNOT be adjusted according to job conditions and and fixture installed to the proper water volume to flush that particular fixture installed.
  • Page 12 SETUP MODES MODES DE CONFIGURATION NOTICE Optional: Only required if factory settings are not preferred. IF ADJUSTMENTS ARE MADE WITHIN 30 MINUTES OF INITIAL POWER-UP: 1. Proceed to “Setup Modes”. IF DESIRED ADJUSTMENTS ARE NOT MADE WITHIN 30 MINUTES OF INITIAL POWER-UP . The power must be disconnected for 10 seconds and then reconnected to obtain another adjustment period.
  • Page 13 Step 2. SeNSOR ADJUStMeNt SettING (see Figure 12C) Figure 12 1. Cycle through the bowl length or Urinal sensing distance by pressing the electronic override button (Y-1). 2. Verify bowl length or Urinal sensing distance. 3. Press and hold the electronic override button (Y-1) for 5 seconds and release Blue it when a solid blue light is visible.
  • Page 14 Avoid directing water spray or cleaners directly at sensor lens. Ce robinet de chasse d’eau Delta Commercial est conçu et fabriqué conformément aux normes les plus élevées de qualité et de performance. Avec un entretien approprié, il offrira des années de service sans problème.
  • Page 15 REPAIR PARTS PIÈCES DE RECHANGE Page 15 - 27 216040, Rev. C...
  • Page 16 AVIS  Les quantités par paquet peuvent varier. Consultez la section des pièces de la dernière liste de prix des robinets commerciaux Delta pour connaître les quantités actuelles.  Pour les soupapes fabriquées avant janvier 2013, vous devez remplacer l’ensemble du diaphragme 061323A / 061324A et l’assise en laiton 062007A avec joint torique.
  • Page 17 Consultez le manuel des pièces de rechange et d’entretien du robinet de chasse d’eau TECK pour plus de pièces et d’informations.  Les quantités par paquet peuvent varier. Consultez la section des pièces de la dernière liste de prix des robinets commerciaux Delta pour connaître les quantités actuelles.
  • Page 18 TABLE 1 - CAP/PIN/DIAPHRAGM CONFIGURATION TABLE TABLEAU 1 - TABLEAU DE CONFIGURATION CAPUCHON/GOUPILLE DE VERROUILLAGE/DIAPHRAGME Urinal Water Closet Urinoir Toilette   Adjustable Adjustable Fixed Fixed Réglable Réglable Fixe Fixe    0 .5 gpf (1 . 9 Lpf) 1 .
  • Page 19 Sensor range needs to be Inadvertent flushing See section “Setup Mode Adjustments” on page 12 one using the adjusted. instructions. fixture. If the issue persists, contact Delta Commercial Technical Service at 1-800-387-8277 (Canada). NOTICE Page 19 - 27 216040, Rev. C...
  • Page 20 Inlet filter may be partially or 2. Replace inlet filter if required. completely obstructed. “Inlet Filter Maintenance (see Figure 14)” on page 23 instructions. NOTICE If the issue persists, contact Delta Commercial Technical Service at 1-800-387-8277 (Canada). Page 20 - 27 216040, Rev. C...
  • Page 21 Consultez la section “Réglages du mode d’installation” à la page toilette ou l’urinoir. 12« pour les instructions. Si le problème persiste, communiquez avec le service technique de Delta Commercial au 1-800-387-8277 (Canada). AVIS Page 21 - 27 216040, Rev. C...
  • Page 22 “Entretien du filtre d’arrivée d’eau (voir Figure complètement obstrué. 14)” à la page 23 pour les instructions. Si le problème persiste, communiquez avec le service technique de Delta Commercial au 1-800-387-8277 (Canada). AVIS Page 22 - 27 216040, Rev. C...
  • Page 23 MAINTENANCE ENTRETIEN INLET FILTER MAINTENANCE (see Figure 14) Figure 14 1. Remove plug button (D-1) and close supply stop (D) using a straight screw driver. 2. Using a wrench remove the retaining nut (F-2) from the supply stop (D). 3. Separate the flushometer tail (F-1) from the supply stop (D). 4.
  • Page 24 CAP/SOLENOID & REGULATING SCREW ASSEMBLY Figure 15 MAINTENANCE (see Figure 15A-B) 1. Close the supply stop (D). 2. Remove the two cover screws (F-3) and lift off metal cover (F-4). 3. Disconnect the solenoid extension cord (R) from the solenoid wires (F-8). 4.
  • Page 25 DIAPHRAGM/GUIDE ASSEMBLY AND SEAT Figure 16 MAINTENANCE (see Figure 16) 1. Close the supply stop (D). 2. Remove the two cover screws (F-3) and lift off metal cover (F-4). 3. Disconnect the solenoid extension cord from the solenoid wires (F-8). 4.
  • Page 26 Changes or modifi cations not expressly approved by the manufacturer could void the user’s authority to operate the equipment. WARNING CAN ICES-3 (A) / NMB-3(A) 2023 Masco Canada Ltd. © For further technical assistance, call Delta Commercial Technical Service at 1-800-387-8277 (Canada) or 1-877-509-2680 (U.S.A.). 255069, Rev H Page 26 - 27 216040, Rev. C...
  • Page 27 L’utilisation de cet appareil dans un endroit résidentiel peut causer des interférences nuisibles, auquel cas l’utilisateur devra corriger les interférences à ses propres frais. AVERTISSEMENT Tous changements ou modifi cations non explicitement approuvés par Delta risquent d’annuler le droit de l’utilisateur à utiliser l’équipement. CAN ICES-3 (A) / NMB-3(A) ©...

Ce manuel est également adapté pour:

Teck ii 81t201-wmshwaTeck ii 81t231-wmshwa