Télécharger Imprimer la page

American Standard Advanced Clean 100 SpaLet 8017A60GRC-291 Instructions D'installation page 16

Publicité

Les langues disponibles

Les langues disponibles

When multiple bidets are installed, a bidet in other booth may also respond to the signal and malfunction.
To prevent this, you can change the signal using the remote control unit you purchased. Change both the
emitting signal (remote control unit) and receiving signal (bidet body).
1. Changing emitting signal
(remote control unit)
(1) Remove the batteries from
the remote control unit.
(2) Refer to the signal table
on the right, hold down
the desired button, insert
the batteries and wait for
six seconds with the button
held down.
(3) When the emitting signal
has been changed, the
battery mark on the lower
right of the remote control
unit LCD flashes.
(The number of flashes
differs depending on
the signal that has been
changed.)
When multiple bidets are installed:
Signal
Operation Button
Number
Signal 1
Water Temp
Signal 2
Seat Temp
Signal 3
Power save
Signal 0
Nozzle Cleaning
Signal 4
Hr
Signal 5
Min
Signal 6
Auto clean
Signal 7
Dryer temp.
* Signal 0 is the default setting.
-16 EN-
2. Changing receiving signal
Battery Mark
(bidet body)
No. of Flashes
Once
(1) Remove the power plug of
Twice
the bidet for which the signal is
Three times
to be changed.
Four times
Five times
(2) Insert the power plug again,
and then press the [STOP]
Six times
button at least 10 times within
Seven times
10 seconds after insertion.
Eight times
NOTE: Do not turn on and off
the indoor (equipment) breaker
to perform the above operation.
* If power is turned on
simultaneously for multiple
bidets, the receiving signal of
other bidets may be changed.
* Some signals cannot be set on
some products.