Télécharger Imprimer la page

Kübler MWE30 Instructions D'utilisation page 21

Publicité

Les langues disponibles

Les langues disponibles

c) During this installation, the carriage and the measuring
wheel are moved upwards by 5 mm [0.2"] (3[} 2]).
Influence of the measuring wheel size
When the surface of the material to be measured and the in-
stallation surface of the system are located at the same
height, the recommended measuring wheel circumference is
200 mm [7.87"].
This results in a maximum spring travel of the measuring
wheel of ±5 mm [±0.2"].
If a measuring wheel with another circumference is used, the
height of the surface of the material to be measured and the
height of the installation surface must be chosen so that the
working range of the measuring wheel system, i. e. the max-
imum spring travel, is not exceeded.
4.1.2.3 Measuring Wheel Pressure Force
Spring travel in mm [inch]
Operation Manual R60104.0009 - 01
NOTICE
IMG-ID: 36028797261570827
(1)
Recommended preload
(2)
Maximum working range
(3)
Pressure force related to the spring travel
4.1.3 Changing the fastening possibilities
The following preparations can be made to carry out the
change:
• Tools
– Hexagon wrench/bit (Inbus
– Hexagon wrench/bit (Inbus
Mounting the encoder:
a) The encoder can be mounted in 30° steps, paying atten-
tion to the encoder cable outlet (B[} 3]).
b) At the desired position, tighten the three M3 screws
(C[} 3]).
Mounting the measuring wheel:
a) Place the measuring wheel on the encoder shaft and push
it entirely towards the encoder until the stop (D[} 3]).
b) The set screw must be placed on the flat of the encoder
shaft. Tighten it (D[} 3]).
®
) SW2
®
) SW2.5
EN | 21

Publicité

loading

Ce manuel est également adapté pour:

Mwe31