Télécharger Imprimer la page

Haverland HHAD03-10C Mode D'emploi page 18

Publicité

Les langues disponibles

Les langues disponibles

EN
switched on and off by the utility.
• The heater must not be located immediately below a
socket-outlet.
• Means for disconnection having a contact separation in
all poles must be incorporated in the fixed wiring in
accordance with the wiring rules.
• For correct installation on the wall, thanks to refer to
'Installation on wall' part.
• Fixed heaters are to be installed so that switches and
other controls cannot be touched by a person in the bath
or shower.
• Connect the two conductors and the pilot wire of the
supply cord to a connection box in respecting the
following polarities:

• Live: Brown

• Neutral: Blue
• Pilot wire: Black
• WARNING: In order to avoid overheating, do not cover
the heater.
Warning: this product shall be installed in the volume 2
or hors volume only according to the national wiring
rules (For France NF C 15-100)
Note: The below drawing is for reference only.
We suggest you to contact a professional electrician for
assistance.
In the case as of buildings room, a room receiving a bath
or a shower and socket-outlets lower or equal to 32 A the
circuit corresponding must be protected by a device with
18

Publicité

loading

Ce manuel est également adapté pour:

Hhad03-15cHhad03-20c