DIP Switch Settings
ON
1
2
3
4
5
6
7
8
DIP 1: LEDs operation
On: LEDs Enabled
Off: LEDs Disabled
DIP 2-3: Detection Sensitivity
Sensitivity
DIP2
Low
Off
Mid
Off
Normal
On
(Default)
Maximum*
On
* In maximum sensitivity sway
recognition is disabled to achieve
maximum sensitivity
Microwave Adjustment
Adjust Microwave coverage area by using the trimmer on the PCB.
Walk test
Two minutes after applying power, walk test the protected area to
verify proper operation.
For installations on uneven surfaces slide the PCB inside the internal
base to the appropriate setting according to the desired height (1.0m,
1.5m, 2.2m, 2.7m) as printed on the bottom left corner of the PCB or
use the standard swivel accessory.
For reducing the detection range, slide the PCB up or tilt the
swivel down.
LEDs Display
LED
State
Steady
YELLOW
Flashing
Steady
GREEN
Steady
RED
Flashing
Flashing (One
All LEDs
after another)
:
Notes
1. DIP-Switch 1 should be in ON position to enable LED indications.
2. Only one LED is active at any one time. For example, in the case of both PIR and MW detection, either the
steady YELLOW LED or the steady GREEN LED is displayed (the first to detect), followed by the Alarm RED
LED.
Relay Mode / BUS Mode Jumper
J-BUS jumper (located on the PCB between the red and green LEDs)
is used to define the detector's mode of operation as follows:
DIP 4: Alarm condition
Factory
Default
DIP 5: Detector's optics
DIP 6: Red LED /3 LED
DIP3
Off
DIP 7: Anti masking operation
On
Off
DIP 8: Vibration detection (applicable to versions
On
Description
Indicates PIR detection
Indicates AM (Anti mask) detection
Indicates MW detection
Indicates ALARM
Indicates malfunctioned communication with ProSYS (BUS
mode only)
Unit initialization on power up
WatchOUT DT Installation Manual
On: PIR or MW
Off: PIR + MW
On: Barrier / Long range
Off: Wide angle
On: Red LED only
Off: 3 LEDs
On: Enabled
Off: Disabled
with Vibration sensor installed)
On: Enabled
Off: Disabled
MIN MAX
PCB
1.00M
1.50M
2.20M
2.70M
Relay
BUS
Mode
Mode
7