RISCO Group Watch OUT Guide D'installation page 15

Détecteur extérieur à double technologie

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51
3. Place the cursor on the TYPE field and use the
WatchOUT DT detector.
/
4. Press
5. Repeat the process for the other BUS detectors.
2. Assigning the WatchOUT DT to a Zone
1. From the main installer menu enter Zones: One by One option (Quick key [2][1])
2. Select the zone number that you want to assign the BUS detector.
Note:
If you defined a BUS Zone Expander, select a zone number from the virtual zones (defined by the BUS zone
expander).
3. Define Partitions, Groups, Zone Type and Zone Sound.
4. In the Termination category select [5] BUS Zone followed by
The following display appears:
Z:001
Z:001
LINK TO:
LINK TO:
ID:01
ID:01
TYPE=ODT15
TYPE=ODT15
5. Select the BUS zone number to assign to the programmed zone. The type field will be
updated automatically when selecting the zone.
/
6. Press
following display appears:
Z:001
Z:001
RESPONSE:
RESPONSE:
N/A-BUS ZONE
N/A-BUS ZONE
/
7. Press
3. Configuring the WatchOUT DT Parameters
1. To access the WatchOUT settings option press [2][0][3] from the main installer menu. The
following display appears:
B-ZONE PRMS:
B-ZONE PRMS:
ZONE#=001
ZONE#=001
(M:ZZ)
(M:ZZ)
2. Select the zone that the BUS zone was assigned to and press
now program the WatchOUT parameters as follows:
Zones Miscellaneous: BUS Zone
Quick Keys
Parameter
[2][0][3][zzz]
LEDS
[1]
Defines the LEDS operation mode.
[2][0][3][zzz]
Off
[1][1]
Disables the LEDS operation.
[2][0][3][zzz]
Red Only
[1][2]
Only the Red led will operate. This option is highly recommended to avoid the
possibility that the intruder will "Learn" the detector behavior.
[2][0][3][zzz]
3 LEDS
[1][3]
All 3 LEDs will operate.
[2][0][3][zzz]
PIR Sensitivity
[2]
Defines the sensitivity of the detector(MW + PIR)
[2][0][3][zzz]
Sensitivity Options
[2][1]..[4]
1) Low
2) Medium
[2][0][3][zzz]
MW Range
[3]
Defines the microwave channel range. The maximum is 23m.
to confirm.
. The loop response category is not applicable to a BUS zone and the
, assign label and press
3) Normal
4) High
WatchOUT DT Installation Manual
/
key to select ODT15 for the
/
/
.
/
Default
3 LEDS
Normal
Trimmer
.
. You can
15