Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply
cord.
Use a UL listed strain relief.
Disconnect
power before making electrical
connections.
Connect
neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected
to
green ground connector.
Connect
remaining
2 supply wires to remaining
2 terminals
(gold).
Securely
tighten all electrical
connections.
Failure to do so can result in death, fire, or
electrical
shock.
Direct Wire
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain
relief.
Disconnect
power before making electrical
connections.
Connect
neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected
to
green ground
connector.
Connect
remaining
2 supply wires to remaining
2 terminals
(gold).
Securely
tighten
all electrical
connections.
Failure to do so can result in death, fire, or
electrical
shock.
Z
1.
Disconnect
power.
2.
Remove the hold-down
screw and terminal
block
cover.
D
A. Neutral ground wire
B. External g round conductor screw
C. Centel,
silver-coloredterminal
block screw
D. Terminalblock cover and hoM-
down
screw
3.
Install strain relief.
Style 1 : Power supply cord strain relief
Remove the screws from a s/4" (1.9 cm) UI_ listed strain relief (UI_ marking
on strain
relief).
Put the tabs of the two clamp
sections
into the hole below
the terminal
block
opening
so that one tab is pointing
up and the other is pointing
down, and hold in
place. Tighten
strain relief screws enough
to hold the two clamp
sections together.
s_ _
_
A. Strain
refief tab pointing
up
B. Hole below
terminal
block
opening
C. Clamp
section
D. Strain
refief tab pointing
down