DANGER!
▶ Heed the operating manual for the UVC clarifier and the pump, especially the chapters on safety,
commissioning and operation!
1. Place the filter on the pond bank (⌦F).
2. Place the pump on a solid surface as horizontal as possible in the pond so that the filter housing
of the pump is covered by at least 20 cm of water. Pay attention to the maximum pond depth (see
Technical data).
Switching on the pump and UVC clarifier
1. Insert the respective mains plug into the mains socket.
Attention: The pump starts immediately!
Switching off the pump and UVC clarifier
1. Remove the respective mains plug from the mains socket.
Maintenance
DANGER! Electric shock!
▶ Before all maintenance work, disconnect the mains plugs of the pump and the UVC clarifier.
DANGER!
▶ Heed the operating manual for the UVC clarifier and the pump, especially the chapters on safety and
maintenance.
CAUTION! Material damage.
▶ Do not use hard objects or aggressive cleaning agents for cleaning.
The following sections describe maintenance work necessary for optimum and fault-free operation.
Regular maintenance prolongs the service life and assures functionality of the appliance over a long
period.
Cleaning the filter
The inside of the filter must be checked approximately every 4 weeks and cleaned according to the degree of
soiling. To do so, proceed as follows:
1. Remove the mains plugs of the pump and the UVC clarifier.
2. Open the filter housing.
3. Remove the filter from the housing (⌦C).
4. Remove the EHEIM FILTERBIO or EHEIM FILTERMECH granules from the filter housing.
5. Clean the filter and the granules under cold, running water.
6. Clean the inside of the filter housing with a water jet.
7. Install the filter again in reverse order (⌦C).
Clearing faults
DANGER! Electric shock!
▶ Before clearing faults, remove the mains plug.