Safety recommendations for maintenance
Before doing any maintenance work, depressurise the water system and isolate the pump from all energy
sources.
When the jobs are done, before restarting the pump, check that no tools, rags or other materials have been left
close to moving parts or in hazardous zones.
Replace any excessively worn components with original parts and use the lubricants recommended by the
manufacturer.
Dispose of the worn-out components and lubricants in accordance with the relevant statutory requirements.
Carry out the routine maintenance procedures specified by the manufacturer to keep the pump safe and per-
forming well.
Frequency
Every working day
Every 50 working hours
Every 500 working hours or
every year
Every 1000 working hours
(1) This interval refers to the first oil change only
English language
MAINTENANCE INSTRUCTIONS
Scheduled service table
Component
Filter
Pump
Connection of pump to power
source (pulley, belt, coupling)
Pump
Pipes and connections
Pump
Pump
Pump gaskets
Valves
Procedure
Inspect filter cartridge
Oil level check
Inspection
Inspect mounting
Inspection
Oil change
(1)
Oil change
Replacement
Replacement
38
7
Reference
See "Inspecting the filter"
See "Checking the oil level"
See "Inspecting the pump
mounting"
See "Inspecting the connec-
tions and pipes"
See "Changing the oil"
See "Changing the oil"
Contact an authorised service
centre
Contact an authorised service
centre
Use and Installation