Safety recommendations for installation
Take all possible precautions to allow the pump to be
installed in a safe, risk-free manner.
All installation phases must be taken into considera-
tion when designing the machinery or plant in which
the pump is to be installed.
Installation
The mechanical connection between the pump and the
motive power source may be made by means of a pulley
and belt, or a flexible coupling.
The crankshaft rotation is in the direction shown in the
figure.
The water supply connection can be made equally well
to the intakes on the right or left of the pump (see fig-
ure).
A) Temporary oil plug
B) Oil plug with breath-
er
C) Intake port
D) Delivery port
Mounting the pump
The pump must be installed on a horizontal surface with no flexible components between it and the mounting sur-
face.
Secure the pump to the support with screws of suitable diameter and length, fixing them through four of the twelve
holes provided in the pump body.
English language
INSTALLATION INSTRUCTIONS
D
C
C
UN003469-AV
The design must consider all mounting points, the
means of transmission of the energy sources, and
the protective and safety devices required by the rel-
evant regulations to prevent the risk of injury.
Only connect the pump to filtered, clean water sources.
Unscrew the plugs fitted on the various ports in the fac-
tory by the manufacturer, and screw the plugs onto the
ports not used, depending on connection requirements.
Replace the oil plug (A), used for shipment with the
breather plug (B) supplied.
D
D
32
D
C
C
Use and Installation
5