Télécharger Imprimer la page

Güde Eco Wheeler ST 415 PII Traduction Du Mode D'emploi D'origine page 36

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
ENGLISH
32
Inspection and maintenance plan
Regular servicing period
Engine oil
(10W-40)
Air filter
Spark plug
Provide appropriate servicing upon the earlier of the following: in the given month or after the specified hours of
operation have expired.
Defects searching
Defect
The motor does not start
Grass is not collected
Before
any start-
up
Inspection
Change
Inspection
Change
Inspection
Clean
Change
Cause
Primary pump has not been used
Lack of fuel
Bowden cables are too long
Wrong fuel, storing without petrol tank
being drained
Sooted spark plug (carbon residues on
electrodes), electrodes distance too big
The spark plug is wet from petrol
(oversaturated engine).
Blocked channel
Full collection bag
Too wet grass
After 1
After 3
month
months
5
25 Hours
Hours of
of opera-
operation
tion
Measure
Use the primary pump
Add some fuel
Adjust the Bowden cables using the
20
coupling nut.
Drain the fuel tank and carburettor.
Add fresh petrol.
Clean the spark plug, check the plug ther-
mal value, possibly change the plug, set
the electrodes distance to 0.6-0.7 mm
Dry the spark plug out and refit it.
Clean the ejection channel
Empty the collection bag
Cut in dry weather
After 6
After 12
months
months
50 Hours
100 Hours
250 Hours
of opera-
of opera-
tion
tion
20
After 24
months
of opera-
tion

Publicité

loading

Ce manuel est également adapté pour:

5117