Télécharger Imprimer la page

SSS Siedle CVB 850-1 Information Produit page 18

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Programming
Overview of functions
Storey call
The storey call button (ERT) is used
to call into the apartment from an
apartment door. Application e.g.
apartment building with 4 apart-
ments and a common staircase.
Storey call buttons are installed in
front of every apartment front door.
Switching on the light
If you press the door release button
twice, the lighting is switched on,
provided your electrical installer has
connected it.
Muting the bell
If you press the speech button twice,
all the ringtones are switched off
and back on. To indicate the muting
function, the LED display is red. If a
visitor rings the doorbell, the button
flashes for as long as the indoor
device is muted.
18
Accepting door calls
The call can be accepted by pressing
the speech button within 45 seconds
after the last ringtone. The call is
ended by briefly pressing the speech
button again. The indoor telephone
only ever transmits speech in one
direction and switches over auto-
matically. If the automatic switchover
function does not work due to loud
incidental noises at the door station,
it is possible to force switch over
of the speech direction from the
indoor device to the door station
by pressing and holding down the
speech button.
Selecting a door station
Press the speech button to establish
a connection to the door station
from where the last call came.
Display LED 1 "Operation"
LED flashes evenly
(System ramp-up)
LED flashes short on, long off
(Operation display, system is functional)
LED flashes short on, long off
(Programming mode active)
LED remains alight
(Plug+Play programming is active)
Display LED 2 "Fault"
LED flashes unevenly
(More than 10 users)
LED flashes unevenly
Unsuitable device connected in
Plug+Play mode
LED flashes evenly
No door station connected in
Plug+Play mode
Important remarks prior to
programming
On principle, the SET CAB/
CVB 850-... can be commissioned
and programmed by one person.
• Complete the installation
• Activate programming mode on
the SNG 850-... set line rectifier
• Set the door station to the pro-
gramming mode
• Program the indoor device
• End programming mode
While the SNG 850-... is in the pro-
gramming mode, several steps can
be programmed in sequence. There
is no need to quit the programming
mode after every operation.
0,3s
0,3s
0,3s
0,3s
1s
20ms
1s
20ms
0,3s
2s
2s
0,3s
0,3s
0,3s
0,3s
0,2s
2s
2s
2s
0,3s
etc.
etc.
0,3s
etc.
0,3s etc.
etc.
etc.

Publicité

loading

Ce manuel est également adapté pour:

Cvb 850-2