Télécharger Imprimer la page

GYS IMS PRO 220E FV CEL Mode D'emploi page 26

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
TROUBLESHOOTING
This device integrates a default management system. In the event of a default, error messages may be displayed.
Error code
«UE1»
«UE2»
«HE1»
«HE2»
«HE3»
«HE4»
«SE»
All operations requiring the removal of the machine's cover and checking the electrical systems must be done by a qualified technician.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported.
26
IMS 220E FV CEL
Meaning
"Exceeding the duty cycle
Ambient temperature above 40°C
Thermal protection
Blocked air inlets
"
Mains overvoltage fault
Mains voltage outside maximum tolerance
Mains undervoltage fault
Mains voltage outside minimum tolerance
Fan fault
The fan is not running at the right speed.
Power relay control fault
The power relay could not be closed
Settings memorisation fault
The EEPROM memory is defective
No temperature information
The temperature sensors are disconnected
One or more buttons on the keyboard are
Defective keyboard buttons
permanently short-circuited
Software Error
Communication problemn
CAUSES
"Wait for the indicator to turn off before resuming
welding operations.
Observe the operating factor and ensure good
ventilation"
Have the sensors connection checked by a qualified
person.
Have your electrical installation checked by a qua-
lified person. The mains voltage must be between
95Vrms and 265Vrms.
Check for foreign bodies that could slow down the
fan, check the correct wiring, replace the fan
Have the wiring of the relay control system checked
by qualified personnel
Contact your reseller
Have the sensor wiring checked by qualified staff
Replace the keyboard
Contact your reseller
EN