Fig. 14
•
Install the fl ue pipe into the fl ue outlet
Mounting the door knob
Fig. 15
•
Screw the door knob on the handle.
Installing the ash lip
Fig. 16
•
Install the ash lip by hanging it under the door.
4.3 Chimney and fl ue pipe
•
The fi replace must only be connected to a chimney and
fl ue pipe approved for solid fuel fi replaces with fl ue gas
temperatures as specifi ed in «2.0 Technical Data».
•
The specifi ed distance to fl ammable materials, applies to
this stove.
•
The stove must be installed with a CE approved fl ue.
•
The distance of the fl ue pipe to combustible materials must
also be observed.
•
The cross-section of the chimney must be designed to fi t
the fi replace. Use «2.0 Technical Data» to calculate the
correct chimney cross-section.
•
The chimney must be connected in accordance with the
installation instructions of the chimney supplier.
•
Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the fi replace and the hole in the chimney. See fi g. 1 for
minimum dimensions.
•
With a rear outlet, use a fl ue pipe bend with a sweep hatch
to allow sweeping.
•
Please note that it is extremely important for connections
to have a degree of fl exibility. This is to prevent any
movement in the installation leading to the formation of
cracks.
•
For recommended chimney draught, see «2.0 Technical
Data». For fl ue pipe dimension see "2.0 Technical Data".
NB: The chimney's diameter must be at least just as
big as the fl ue pipe.
NB! The minimum recommended chimney length is 3.5 m
from the fl ue pipe insert. If the draught is too strong, a fl ue
pipe damper can be installed and used to reduce the draught.
ENGLISH
11