3. Specifications
Specifications
Dial
Pointer
Zero adjustment for
differential pressure
indication
Case
Window
Weight
Electrical contact
Type of contact
Contact function
Single change-over
Double change-over
Load data
U max., I max., P max.
Switch point setting
Setting range
Switch point
reproducibility
Switch hysteresis
Electrical connection
1) I max. = 1.4 A for designs in accordance with VdTÜV code of practice Flow "100"
For further specifications see the corresponding product label, WIKA data sheet
and order documentation.
For models with optional explosion protection read the "Additional information
for hazardous areas (Ex i), models DPS40, DPGS40, DPGS40TA und DPGT40",
article number 14110818.
WIKA operating instructions DPGS40TA with component testing
Differential and working pressure indication: White dial, black
lettering
Differential and working pressure indication: Blue pointer
Via screw in the dial
Aluminium, EN AC–Al Si9Cu3(Fe), black lacquered
Plastic, with plug screw for zero and switch point adjustment
(option: Lead sealing of the settings)
approx. 1.3 kg
Micro switch
Contact type 850.3
Contact type 850.3.3
250 VAC, 5 A
, 250 VA
1)
from the outside at assistant scale by means of adjustment
screw(s)
from 10 % to 100 % of the full scale value
≤ 1.6 %
max. 5 % of the full scale value (option: max. 2.5 %)
Cable gland M20 x 1.5 with 1 m free cable
30 VDC, 0.4 A, 10 W
EN
17