Where an operating fault occurs, alarms warn you of the type of problem encountered.
1- Temperature
If the temperature of your cabinet is 4°C (7°F) + or – the set temperature for longer than 24 hours, a visual alarm will be
activated.
The pictogram
is displayed and will not disappear until the temperature has returned within the + or – 4°C (7°F) range.
Check that (see temperature alarm chapter, page 9):
- the cabinet door is closed correctly,
- the door seal is not damaged,
- you have not, in the last couple of hours, loaded your cabinet with a large
number of bottles.
Once you have checked all of these points, if the alarm is still active after a few days,
there may be an operating fault. Unplug your cabinet and contact your dealer.
II- Temperature sensors
If the temperature sensors are faulty, the faulty sensor alarm
indicator light ( ) comes on.
It does not go out until the problem has been resolved.
In this case, contact your EuroCave dealer.
III- Lighting
In case of lighting failure, do not touch the casing or the diodes.
Contact your dealer.
N.B.: Whatever the circumstances, if your appliance does not appear to be functioning
normally, contact your EuroCave dealer.
Dimensions in
H
D290
1744
*Consumption per 24hrs measured with an external temperature of 25°C (77°F) and a glass door.
Temperature regulation accuracy: +/- 1°C (2°F) - Display accuracy: +/- 0.5°C (1°F)
Your product meets the following standards:
1 SAFETY (Article 3.1a de la directive 1999/5/CE)
Standard(s)
EN60335-2-24
EN60371 Ed.02
2 EMC (Article 3.1b of directive 1999/5/EC and additional requirements 89/336/EC)
Standard(s)
EN55014-1/A1/A2Ed.00/01/02
EN55014-2/A1/A2Ed.97/02
10 - OPERATING FAULTS
11 - TECHNICAL SPECIFICATIONS
Weight when
(mm)
empty (kg)
W
D**
654
689
92
** Handle included
*** For the 115V-60Hz version
Please note: Any work carried out on the refrigerated
unit must be performed by a qualified refrigerationist, who
should check the circuit for leaks before powering up.
In the same way, any work carried out on the electrical
system must be performed by a qualified electrician.
Permitted temperature ranges
°C/°F)
°C/°F)
Min T° (
Max T° (
12 / 54
30°C / 86°F
N.B.: only prolonged
exposure
to
temperatures outside the
recommended range and
sudden fluctuations in
temperature are harmful
to your fine wines.
Consumption per
24hrs* (kWh)
1,5 / 1,675***
-11-