To prevent
heat damage to the fill valve, ALL solder connections
must be made BEFORE the water line
is connected
to the dishwasher.
.
DRAIN
LINE
The drain line should be 9/,6" (14 mm) ID (minimum)
flexible
hose or 5,'~" (16 mm) OD copper tubing.
Flexible
hose must be resistant
to heat and detergent
and may be obtained
from a plumbing,
hardware,
or automotive
supply
outlet.
DO NOT use any fittings
anywhere
in the drain line that are less than
l/2"
(13 mm) ID. The
access hole for the drain line should
be 1' (25 mm).
If drain line is copper,
clamp a 12" (305 mm) length of g/ 16" (14 mm) ID flexible
hose (heat and detergent
resistant) to the end of the copper tubing. This will facilitate connection
of the drain line to dishwasher
check valve.
If the drain line is going to be connected
to a food waste disposer,
BE SURE to remove the knockout
or plug
from the fitting
on the disposer
before
connecting
drain
line. Rubber
adapter
fitting
may be required.
(KitchenAid
part number
115739 or available
from local hardware
or plumbing
stores.)
Typical drain connections
to sink plumbing
are shown in Fig. 5 & 6.
Dra '1 or disposer connectlon
'
~~ --y-- ---
~~~ -__
I
I
I
J , 'LJ
k--IL
"If &a," hne IS flex;bie-hose
lhls dlmenslon IS
22" (559 mm)
If drain line IS copper.
the copper should be
12" (305 mm) plus a
12" (305 mm) length of
flexible hose attached to
Ihe end
Air Gap
II drain lme IS copper,
the copper should be
12" (305 mm) plus a
12" (305 mm) lenglh of
flextble hose attached lo
the end
_ 4"
(108
r7m;
Fig. 5
(;84r&rn)
Fig. 6
Typlcal
drain connection
to an air gap (If required
by
local code) IS shown in
Fig. 6.
IF DRAIN IS ROUTED
TO A CONNECTION
POINT LESS THAN 20" (508 mm) ABOVE THE FLOOR,
THE DRAIN
LINE MUST BE MADE TO FORM A HIGH LOOP TUBE (SHOWN
IN FIG. 7).
FAILURE
TO PROVIDE
EITHER THE PROPER DRAIN CONNECTION
HEIGHT (20" (508 mm) ABOVE
FLOOR LEVEL)
OR A 20" (508 mm) HIGH LOOP WILL RESULT
IN IMPROPER
DRAINING
OF THE
MACHINE
WHICH MAY CAUSE
DAMAGE
TO THE MACHINE.
TO FORM THE HIGH LOOP TUBE, SEE INSET ON FIG. 7. MAKE SURE THAT NO KINKS DEVELOP
IN THE HOSE OR COPPER
TUBING.
VB" (16 mm) O.D. Copper tubing
must be at least 20" (506 mm)
I
above floor.
'If drain line IS flexible hose
this dlmenslon IS
22"
(559 mm)
If drain line IS copper,
the copper should be
12" (305 mm) plus a
12" (305 mm) length of
flexible hose allached 10
Ihe end
- a"-
(108
mm)
Fig. 7