Radiation
Operating conditions
Transport and storage conditions
Product classification
Accessories
Colour temperature of the LEDs
Threshold of short wavelength
Maximum light output
Expected service life of the device 10.000 hours
Maximum radiance output of the TL 95
Radiance output
E
: Eye UV-A
UVA
ES: Actinic UV skin & eye
EIR: Infrared radiation hazard exposure
limits for the eye
LIR: Retinal thermal
(mild visual irritation)
LB: Blue light
LR: Retinal thermal
Subject to technical changes.
The serial number is located on the device or in the battery compartment.
Brightness: 10,000 lux (this point about the light intensity is merely for information purposes. With regard
to the standard IEC 60601-2-83, this light source is classified as an Exempt Group).
Notes on electromagnetic compatibility
The device complies with Regulation (EU) 2017/745 of the European Parliament and of the Council on
medical devices and the respective national regulations and the European standard EN 60601-1-2 (in
accordance with CISPR 11, IEC61000-3-2, IEC61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-
4, IEC 61000-4- 5, IEC 61000-4- 6, IEC 61000-4- 11, IEC 61000-4-8) and is subject to particular precauti-
ons with regard to electromagnetic compatibility.
• The device is suitable for use in all environments listed in these instructions for use, including domestic
environments.
• The use of the device may be limited in the presence of electromagnetic disturbances. This could result
in issues such as error messages or the failure of the display/device.
• Avoid using this device directly next to other devices or stacked on top of other devices, as this could
lead to faulty operation. If, however, it is necessary to use the device in the manner stated, this device
as well as the other devices must be monitored to ensure they are working properly.
• The use of accessories other than those specified or provided by the manufacturer of this device can
lead to an increase in electromagnetic emissions or a decrease in the device's electromagnetic immu-
nity; this can result in faulty operation.
• Failure to comply with the above can impair the performance of the device.
Radiance output outside of the visible range (infrared and UV) is
low enough that no eye or skin damage is anticipated.
0°C to +35°C, 15 - 90% relative humidity,
700 – 1060 hPa ambient pressure
-20°C to +60°C, 15 - 90% relative humidity,
700 – 1060 hPa ambient pressure
Protection class II, IP21
Mains adapter, instructions for use
6500K ±400 Kelvin
420 - 680 nm
66.88 W / m²
Risk group classified in accord-
ance with IEC 62471
Exempt Group
Exempt Group
Exempt Group
Exempt Group
Exempt Group
Exempt Group
23
Maximum value
0
0
2.146e-1
7.057e-2
8.867e0
1.187e2