Installing
a 4-wire power cord
A.=o WARNING
The neutral wire of the supply circuit must be connected to the neutral
terminal located in the lower center of the terminal block. The power leads must be connected to the
lower left and the lower right terminals of the terminal block. The 4th grounding lead must be connected
to the frame of the range with the ground plate and the ground screw.
1. Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and
ground plate and retain them.
2. Cut and discard the ground strap. Do not discard any screws.
3. Insert the ground screw into the power cord ground wire terminal ring, through the ground plate,
and into the frame of the range.
4. Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the
lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to
the center lower position of the terminal block. Tighten screws securely to the terminal black.
5. Go to step 5 on page 27 to continue with the installation.
Ground strap
Ground plate
screw
English - 25