Engine Cool-down Timer
• When the load is transferred back to the utility power
source, the engine cool-down timer starts timing.
• The timer will run for about one minute, then the generator
will stop.
• Minimum generator run time is five minutes.
SETTING EXERCISE TIMER
The Home Standby Generator is equipped with an exercise
timer that will start and exercise the generator once every
seven days. During this exercise period, the unit runs for
approximately 20 minutes and then shuts down. Electrical
load transfer DOES NOT occur during the exercise cycle
(unless an utility power outage occurs).
A switch on the control panel is labeled "Set Exercise" (see
page 7). On the specific day and time the switch is pressed,
the control board is programmed. This date and time is then
used to automatically initiate the generator exercise cycle.
To perform the Set Exercise procedure:
1. Choose day and time you want Home Standby Generator
to exercise.
2. On that day and time, set AUTO/OFF/MANUAL switch to
OFF position.
3. Press and hold down "Set Exercise" switch for two
seconds.
INSTALLATION
Download from Www.Somanuals.com. All Manuals Search And Download.
4.
Set AUTO/OFF/MANUAL switch to AUTO. "Set Exercise"
is complete.
For example, if you press the "Set Exercise" switch on
Sunday morning at 10:00 AM, the unit will run an exercise
cycle the following Sunday at 10:00 AM (+/- 1 hour).
NOTE: "Set Exercise" will only work if the unit is in the
Automatic mode and this exact procedure is followed.
If you want to change the day and time the unit exercises,
simply perform the "Set Exercise" procedure at the day and
time you want it to take place.
INSTALLATION INSPECTION
Before placing the Home Standby Generator into service,
inspect the entire installation carefully. Ensure that any
scratches or broken paint on the inside or outside of the
enclosure are touched up with the supplied paint.
Complete the "Installation Checklist" as you make the
inspection. Ensure all items have been filled-in and all
signatures have been obtained. Instruct the owner to mail the
white copy to:
Briggs & Stratton Power Products
Warranty Registration
P. O. Box 239
Jefferson, WI 53549-0239
20