Electrica-
All Models
9
Disconnect
power
before
working
on pump,
motor,
pressure
switch,
or wiring.
1_ CAUTION ]Risk of fire. Never wire a 115 volt motor to a 230 volt line.
Check
Voltage
Setting.
1. Turn off power
to the pump!
2.
Determine
if the power supplied
to the pump is 115
or 230 volts.
3. A qualified
person must install electrical
wiring.
4. The voltage switch
is factory
set to 1 15 volts. If you
have 11 5 volt service,
do not change the selection.
1/2 HP motors are preset at the factory for 11 5 volts.
5. To change the voltage
(if necessary), remove the
motor
capacitor
cover and slide the switch fully to
the correct
voltage.
6.
Reinstall the cover.
Do Not
Turn
On Power
Yet r.
_[___rTo
Motor
Connection_--_(_
,,___.,H
_f_
From Line-
5907 1108
Figure I I: Connect
power
supply wires to pressure
switch
as shown.
Connect
Power
Supply
Wiring
To Pressure
Switch
1. Remove the pressure switch
cover.
2. Attach
power and ground
wires to the pressure
switch as indicated.
3.
Reinstall the cover.
Do Not
Turn
On Power
Yet!
Figure 12A: Remove cover from capacitor
box to
reach voltage
change
slide switch.
Figure 12B: Pump is shipped
from factory
set for
115-volt
operation
(above). To change
to 230-volt
operation,
slide switch
to display "230" (below).
5982 0409
Figure 12C: Slide switch set for 230-volt
operation.