Base Grille Water Filtration System
Model TIWG2L/T2RFWG2
Capacity
200 Gallons (757 Liters)
Model TIWG2/T2RFWG2
Capacity
200 Gallons
(757 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I1"; and against
NSF/ANSI
Standard
53 for the reduction
of Mercury,
Benzene,
Toxaphene,
O-dichlorobenzene,
and Carbofuran.
This system
has been tested according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
Aesthetic
Effects
Chlorine Taste/Odor
Particulate Class I1"
Contaminant
Reduction
Lead: @ pH 6.5***
Lead: @ pH 8.5***
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
O-Dichlorobenzene
Toxaphene
Carbofuran
NSF Reduction
Requirements
50% reduction
85% reduction
NSF Reduction
Requirements
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.005 mg/L
0.6 mg/L
0.003 mg/L
0.04 mg/L
Average
Influent Challenge
Maximum
Average
Minimum %
Influent
Concentration
Effluent
Effluent
Reduction
2.0182 mg/L
2.0 mg/L + 10%
0.06 mg/L **
0.0536 mg/L
97.03
1333333 #/mL
At east 10,000 part c es/mL
6600 #/mL
2325 #/mL
99.51
Average
Influent
0.1533 mg/L
0.1400 mg/L
0.0058 mg/L
0.0059 mg/L
0.0154 mg/L
1.7571 mg/L
0.015 mg/L
0.0819 mg/L
Influent Challenge
Concentration
0.15 mg/L_+ 10%
0.15 mg/L_+ 10%
0.006 mg/L _+10%
0.006 mg/L _+10%
0.015 mg/L _+10%
1.8 mg/L _+10%
0.015 mg/L _+10%
0.08 mg/L _+10%
Maximum
Effluent
0.0005 mg/L
0.0007 mg/L
0.0002 mg/L
0.0005 mg/L
0.0012 mg/L
0.0250 mg/L
0.001 mg/L
0.0400 mg/L
Average
Effluent
0.0005 mg/L
0.0006 mg/L
0.0002 mg/L
0.0003 mg/L
0.0006 mg/L
0.0066 mg/L
0.001 mg/L
0.0213 mg/L
Minimum %
Reduction
99.67
99.50
96.54
91.57
92.22
98.58
93.33
51.13
Test Parameters:
pH = 7.5 _+0.5 unless otherwise
noted.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (2O°C to 22°C). Rated service
capacity
= 200 gallons
(757 liters).
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
Use replacement
filter T2RFWG2,
part #4396841.
2008 suggested
retail price of $39.99
U.S.A./S54.95
Canada.
Prices are subject
to change without
notice.
Model TlWG2L:
Style
1 - When the filter indicator
reads 10%,
order a new filter. When the indicator
reads 0%, it is
recommended
that you replace the filter.
Style 2 - When the filter indicator
changes
from green to yellow,
order a new filter. When the indicator
changes
from yellow to red,
it is recommended
that you replace the filter.
Style 3 - When the water filter status display changes
from
"GOOD"
to "ORDER,"
order a new filter. When the filter indicator
reads "REPLACE,"
it is recommended
that you replace the filter.
Style
4 - Press FILTER to check
the status
of your
water filter. If
the filter indicator
light is yellow,
order a new filter. If the filter
indicator
light is red, it is recommended
that you replace
the filter.
Model TlWG2:
Change the water filter cartridge
every 6 months.
If the water flow to the water dispenser
or ice maker decreases
noticeably
before 6 months
have passed,
replace the water filter
cartridge
more often.
Average %
Reduction
97.34
99.83
Average %
Reduction
99.67
99.57
96.54
94.92
96.34
99.63
93.33
74.00
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
The product
is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown
quality
without
adequate
disinfection
before or after the
system.
Refer to the "Warranty"
section
for the Manufacturer's
name,
address
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate
0.5 gpm (1.9 Lpm) @ 60 psi
*Class II particle size: 1 um to <5 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
***Compliant
for Lead reduction requirements
under NSF/ANSl Standard 53 as tested by Pace Analytical Services, Inc.
® NSF is a registered trademark
of NSF International.