F5
Safety test
F6
Maintained action
F7
Command [2-7]
Obstruction detection
F9
with motor stopped
Gate state warning
F10
output
F11
Encoder
F14
Sensor type
F19
Automatic Closing Time
Automatic closing time
F20
after partial opening
F21
Pre-fl ashing time
F25
Courtesy light time
F30
Slow-down speed
F34
Travel sensitivity
F35
Slow-down sensitivity
Adjusting the partial
F36
opening
Opening slow-down
F37
point
Closing slow-down
F38
point
After every opening or closing command, the board will check whether the photocells are working properly.
The safety test is always active for wireless devices.
This function only appears if the photocells have been enabled.
OFF (default) / 1=CX / 2=CY / 4=CX+CY
The gate opens and closes by keeping the button pressed. Opening button on contact 2-3P and closing
button on contact 2-7. All other control devices, even radio-based ones, are excluded.
OFF (default) / ON
From the control device connected to 2-7 it performs the step-step (open-close-invert) or sequential (open-
stop-close-stop) command.
0 = Step-step (default) / 1 = Sequential
With the gate closed, opened or totally stopped, the gearmotor stays idle if the safety devices, that is,
photocells or sensitive safety-edges detect an obstruction.
OFF (default) / ON
It signals the gate status. The signal device is connected to contact 10-5.
0 = Lit when gate is open or moving (default) / 1 = when opening it fl ashes intermittently every half-
second, when closing it fl ashes intermittently every second, stays lit when gate is open, is off when
gate is closed.
Managing slow-downs, obstruction detections and sensitivity.
OFF / ON (default)
Setting the type of accessory for controlling the operator.
0 = command with transponder sensor or magnetic card reader / 1 = command with keypad selector
(default)
The automatic-closing wait starts when the opening limit switch point is reached and can be set to between
1 and 180 seconds. The automatic closing does not work if any of the safety devices trigger when an
obstruction is detected, or after a total stop, or during a power outage.
OFF (default) / 1 = 1 second /... / 180 = 180 seconds
The wait before the automatic closing starts after a partial opening command for a time of between 1 s
and 180 s. The automatic closing does not work if any of the safety devices trigger when an obstruction is
detected, or after a total stop, or during a power outage.
OFF / 1 = 1 second /... / 10 = 10 seconds (default) /... / 180 = 180 seconds
Adjusting the pre-fl ashing time for the fl ashing light connected to E1-W, before each maneuver. The fl ashing
time is adjustable from one to ten seconds.
OFF (default) / 1 = 1 second /... / 10 = 10 seconds
Additional (courtesy) light, stays lit for the necessary time while the gate is opening and closing.
It can be set to between 60 and 180 seconds.
60 = 60 seconds (default)/... / 180 = 180 seconds
Setting the gearmotor speed during the slow-down stages.
OFF (default) / ON
This function only appears if the Encoder function is activated.
Adjusting obstruction detection sensitivity during gate-leaf travel.
10 = maximum sensitivity / ... / 100 = minimum sensitivity (default)
This function only appears if the Encoder function is activated.
Adjusting obstruction detection sensitivity during slow-down.
10 = maximum sensitivity / ... / 100 = minimum sensitivity (default)
This function only appears if the Encoder function is activated.
Adjustment as a percentage of total travel, during gate opening.
10 = 10% of the gate-leaf travel / ... / 80 = 80% of the gate travel (default)
This function only appears if the Encoder function is activated.
Percentage adjustment of the total door travel, of the opening slow-down starting point.
5 = 5% of the gate run / ... / 25 = 25% of the gate-leaf travel (default) / ... / 45 = 45% of the gate travel
This function only appears if the Encoder function is activated.
Percentage adjustment of the total door travel, from the closing slow-down starting point.
5 = 5% of the gate travel / ... / 25 = 25% of the gate-leaf travel (default) / ... / 45 = 45% of the gate travel
This function only appears if the Encoder function is activated.