Filter operation test
Set the shading number to a value ranging from 9 to 13; press the TEST button; check whether the LCD changes from light to dark,
and then automatically returns to the bright state
Sensor sensitivity
Depending on the welding process and the ambient light, select the minimum amount of light required for the front sensors to
enable the protective screen guard as follows:
• Turn the knob to LO for high current welding in a bright welding environment or in an environment with other interference sources.
• Turn the knob to HI for low current welding or in a low light environment, especially in case of low current argon arc welding.
• Turn the knob half way for most indoor and outdoor welding operations.
Delay time
The amount of time required by the helmet to switch back from full dark to full light.
The delay time ranges from 0.25s to 1.0s. Set the delay time as follows:
• If the minimum value is selected, the delay time will be set to 0,1-0,25s, suitable for spot welding, short welding or seam welding
• If the maximum value is selected, the delay time will be set to 0,85-1,0s suitable for high current welding or preventing eye fatigue
from electric arcs or close viewing of incandescent pieces. adatto per saldatura ad alta corrente o per prevenire l'affaticamento
degli occhi dovuto agli archi elettrici o a visione ravvicinata di pezzi ancora incandescenti.
• The medium value is suitable for most welding operations.
Grinding
To carry out cutting or grinding jobs, set the exterior shade adjusting knob to "GRIND".
TROUBLESHOOTING
FAQs
Filters do not darken, or flickers
Reaction is slow
Filter is not clear
The mask slips
Battery
• Before use, check the battery charge.
Battery fully charged
Battery almost exhusted
• To replace, remove the caps (5) and use two batteries as indicated in the TECHNICAL DATA table
Worn batteries must be disposed of in accordance with local regulations.
10
CAUSES
Protector is damaged
Arc sensor is not clear
Welding current is too low
Battery is low
Ambient temperature is too low
Sensitivity setting is too low
Protector is stained
Protective film has not been removed
Filter lenses have stains
Headband has not been adjusted
not flashing
flashing
SOLUZIONS
Clean or replace it
Clean sensor surface
Adjust sensitivity to maximum
Replace battery
Do not use below -5 °C
Raise sensitivity properly
Clean or replace protector
Remove protective fi lm
Wipe both sides of fi lter lenses
Adjust fixed nuts on headgear
EN