Cleaning The Airless Spray Gun; Maintenance; Lubricating The Upper Packings - Titan Tool ProMark Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

cleanup / maintenance
7.4
cleANINg AIrleSS SprAy guN
Clean the spray gun after each use.
i
1. Rinse airless spray gun with an appropriate cleaning agent.
2. Clean tip thoroughly with appropriate cleaning agent so
that no coating material residue remains.
3. Thoroughly clean the outside of the airless spray gun.
INTAke fIlTer IN AIrleSS SprAy guN
1. Pull the bottom of the trigger guard forward so that it
comes loose from the handle assembly.
2. Loosen and remove the handle assembly from the gun
head.
3. Pull the old filter out of the gun head.
4. Slide the new filter, tapered end first, into the gun head.
5. Place the handle seal into the gun head with the flat side
of the seal toward the gun head.
6. Thread the handle assembly into the gun head until
secure.
7. Snap the trigger guard back onto the handle assembly.
For more detailed information regarding the
i
spray gun(s), refer to the separate spray gun
manual included with the system
30
8

mAINTeNANce

Before proceeding, follow the solvent flush
procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce
the risk of an injection injury or injury from
moving parts.
8.1

luBrIcATINg The upper pAckINgS

1. Clean out any spray material that has seeped past the
upper packings into the oil cup reservoir above the fluid
section.
2. Fill the packing oil reservoir 1/2 full with Piston Lube (P/N
314-480) supplied by the factory. This will extend packing
life.
fIgure 16
Do not over-fill the reservoir so that it overflows
i
and drips into the spray material.
ProMark
hyDrAulIc moTor
oIl cup

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Promark 100Promark 150

Table des Matières