Filling The Solvent Flush Tank; Fill The Pressurized Bead Dispenser - Titan Tool ProMark Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

system preparation
4.2

fIllINg The SolVeNT fluSh TANk

The ProMark system needs to be flushed with
solvent whenever the system remains idle for
more than 2-3 minutes, otherwise the spray
Attention
material mixture will harden inside the mixing
chamber, hoses and spray guns, rendering them
inoperable.
Check the solvent flush level before each use.
It is a good idea to always keep extra solvent
available during jobs.
If purchasing more solvent, it is recommended
i
to use Non-Chlorinated Brake Cleaner (such as
Johnsen's® or Brakleen®).
fIll The SolVeNT fluSh TANk
The blue valve handle at the very bottom of the
solvent tank should be in the open (vertical)
position prior to filling the tank.
1. Open the two brass clasps on either side of the solvent
flush tank lid and remove the lid. The tank lid can hang
from its safety cord.
2. If using the system for the first time, fill the solvent flush
tank with the included solvent. DO NOT fill the tank past
the opening of the outlet on the side of the tank (the top
of the "S"). See figure 6.
3. Replace the solvent flush tank lid and secure with the brass
clamps.
fIgure 6
Do NoT fIll
pAST here
22
4.3

fIll The preSSurIzeD BeAD DISpeNSer

The ProMark system can be used in conjunction
i
with reflective beads.
fIll The DISpeNSer
1. Loosen the wing nuts located around the lid of the bead
dispenser and lay back the tank lid pins.
2. Fill the tank with beads. The tank will hold approximately
80 pounds of beads.
3. Replace the dispenser lid and secure with the wing nuts.
fIgure 7
ProMark
WINg NuT (x5)
preSSurIzeD
BeAD DISpeNSer

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Promark 100Promark 150

Table des Matières