You stop the operation of the timer by pressing on the TIMER ON/OFF button. The
stove will act as if there are no current timer settings and will simply operate
according to the thermostat and output settings. By pressing the TIMER ON/OFF
button again, you reactivate the timer setting.
To erase the timer setting, press on the TIMER SET button. 01 will start flashing on
the display. Using the + and - buttons, look for the setting number that you want to
erase and subsequently press on the C button (erasing the timer setting). The
timer setting will disappear immediately.
ATTENTION! If you want the stove to operate according to a timer programme, it will not
only have to remain on stand-by, but also switched on (using the ON/OFF button). If this is
not necessary, always switch off the stove using the ON/OFF button, switch off the main
switch and remove the plug from the socket.
ATTENTION! Day and time are deleted if the electricity is cut off. This happens not only
when the plug is pulled out of the socket, but also if the main switch is set to O (OFF). The
timer settings however are stored. When the electricity is restored and the timer settings
are entered, then you need to reset the day and hour settings immediately; otherwise the
time will begin at 0.00!
If you do not enter any orders for approx. 15 seconds, the display will turn off. Pressing
any random button will reactivate the display.
Switching off
If you are not using the stove, you must switch it off using the main switch (you press O)
and remove the plug from the socket. Doing this will erases all the settings, also day and
time. Only the timer settings are stored.
Safety feature
The Siena atmospheric fireplace is equipped with an overheating safeguard. In case of
internal overheating, the overheating safeguard will switch the heater off. This may occur
if the heater cannot give off enough heat or if it cannot draw in enough fresh air. As
mentioned above, this is generally caused by (partially) covering the heater, obstructing
the air intake and/or outlet grills or installing the heater too close to a wall or something
similar. If this happens, turn the fireplace off by switching the main switch to O and
remove the plug from the socket. Leave the fireplace to cool down for at least 15 minutes
and remove the cause of overheating. You can then switch the fireplace back on. If the
device overheats again or you cannot ascertain the reason for this, take the fireplace to
your service point to be checked/repaired.
Important! For safety reasons the fire will not automatically restart after overheating.
Check whether conditions are safe before switching it on! So never switch on the heater
43