To insert the lamp (24V/250W or MSD 200W) open the housing by loosening the fastening screws at the side
panels and frontcover. Please use a 24V/250W lamp for the SC-330 and a MSD 200W or MSD 250W lamp for the
SC-370.
Do not install a lamp with a wattage! A lamp like this generates temperatures the device is not designed for.
Damages caused by non-observance are not subject to warranty.
Insert the lamp now. Do not touch the glass-bulb bare-handed during the installation! Please follow the lamp
manufacturer's notes!
Before you close the housing again, make sure that the lamp is installed tightly into the lampholder system.
Reclose the housing and tighten the fastening screws.
Do not operate this device with opened service-lid!
LA M P AD JUSTM ENT SC-570:
CO RRECT
1 4
Optim um distance
1 - 1.5 m m
INCO RRECT
Keep optim um
distance to lens!
1 - Fastening screws
2 - Fixation screw for bracket
3 - Bracket
4 - Focus-screw
5 - Objective
6 - Mirror