Télécharger Imprimer la page

Yamaha 200G Manuel D'utilisation page 176

Publicité

102024
q
w e
EMU00409
MOTOR EXTERIOR
EMU00410
Cleaning the Outboard Motor
After use, wash the exterior of the out-
board with fresh water.
Flush the cooling system with fresh water.
NOTE:
Refer to Flushing Cooling System instruc-
tions in "TRANSPORTING AND STORING
OUTBOARD MOTOR".
EMU01111
CLEANING COOLING-WATER
PASSAGES
Flushing device equipped model
Perform this procedure right after opera-
tion for the most thorough flushing.
1) After shutting off the engine, unscrew
the garden-hose connector 2 from
the fitting 1 on the bottom cowling.
2) Screw the garden-hose connector 2
onto a garden hose 3 which is con-
nected to a fresh-water supply.
3) With the engine off, turn on the water
tap and let the water flush through
the cooling passages for about 15
minutes. Turn off the water and dis-
connect the garden hose 3.
4) When flushing is complete, reinstall
the garden-hose connector 2 on the
fitting 1 on the bottom cowling.
Tighten the connector securely.
cC
Do not leave the garden-hose connector
loose on the bottom cowling fitting or let
the hose hang free during normal opera-
tion. Water will leak out of the connector
instead of cooling the engine, which can
cause serious overheating. Be sure the
000842
connector is tightened securely on the fit-
ting after flushing the engine.
4-25
GB

Publicité

loading