6.2 Extended settings
6.2.1 Tolerance setting
Tolerance setting allows subsequent adaptation of the tolerance range to the
colour teaching performed last�
The unit features 5 selectable tolerance steps (→ 4 Operating and display ele-
ments):
- Tolerance step 1: minimum deviations (RGB colour values or shade, bright-
ness and saturation) from the colour to be detected are tolerated�
- Tolerance steps 2 - 5: larger deviations are tolerated�
The factory setting of the unit is tolerance step 2�
► Press [OUT off] for 6���10 s�
> The green LED flashes with the tolerance step set last (2 Hz)�
1
► Release [OUT off]�
> The yellow LED indicates the switching status (irrespective
of AT)�
Selection of the tolerance step�
Increase the tolerance step (up to the max possible tolerance
step*)�
► Press [OUT on]�
2
Decrease the tolerance step�
► Press [OUT off]�
> The green LED flashes according to the tolerance step
selected�
Acknowledgement of the selected tolerance step�
► Press [OUT on] and [OUT off] simultaneously�
3
If the selection is not acknowledged, the unit saves the selected
tolerance step automatically after 15 min�
*) LED flashes green 8 Hz� Colour teaching with a higher tolerance step is not possible�
6.3 Electronic lock
The unit can be locked electronically to prevent unauthorised setting� On delivery
the unit is not locked�
► Press [OUT on] and [OUT off] simultaneously for 10���20 s�
> Acknowledgement is indicated by a change of the LED
switching status�
► To unlock repeat this step�
18