6.1.2 The sensor is not to switch when the colour is detected
1 ► Position the light spot on the colour surface to be detected�
► Press [OUT off] for 2���6 s�
> Yellow LED flashes (2 Hz)�
2
► Release [OUT off]�
> LEDs go out
After 1 s the setting is completed�
> The yellow LED indicates the switching status (irrespective
3
of AT)�
> The green LED indicates the set tolerance step�
Unit is ready for operation�
6.1.3 Colour teaching failed
1
> Yellow LED flashes quickly, 8 Hz�
If colour teaching with a lower tolerance step is possible, the
unit changes into the tolerance setting mode�
> Highest possible tolerance step is flashing�
> The yellow LED indicates the switching status (irrespec-
tive of AT)�
2a
► If necessary, adapt the tolerance step (→ 6.2.1 Tole-
rance setting)�
► To acknowledge the tolerance step press [OUT on] /
[OUT off] simultaneously�
Setting operation completed�
If colour teaching is not possible due to too low or too high
a colour intensity, the unit returns to the normal operating
2b
mode with unchanged values�
Setting operation stopped�
UK