Independent of the described conditions of use, the
following signs indicate that the device should un-
dergo maintenance:
The noise level coming from the fan is higher
than normal.
heavily-polluted air filters
polluted electrode (typical sign: the hissing
sound produced during the ozone generation
is only barely audible)
Cleaning
Within the framework of the maintenance work to be
carried out on a regular basis, you should not only
check the proper condition of the device and its as-
semblies but also carry out a comprehensive cleaning
of the device and its components.
Proceed as follows:
Cleaning the air filter
Remove the filter boxes on the back of the
device.
Remove the air filter.
Please use a soap solution for cleaning the air filter.
After cleaning, do not insert the filter before it is com-
pletely dry.
Additionally, the air filter should be exchanged after
approx. 2 - 3 uses to prevent pollution of the device.
Cleaning the interior
Remove the screws on the housing.
Carefully remove the back side.
Clean the device. Only use compressed air or
a moist cloth for cleaning.
Caution!
Damage to the device due to im-
proper cleaning!
Do not use cleaning agents con-
taining solvents to clean the de-
vice. Do not apply any liquids to
the interior of the device. Do not
use a water jet.
B-10
Mount the housing back on correctly. Make sure that
the safety switch (1) is closed (fig. page 9).
Cleaning the electrode
The electrode can be cleaned in its built-in state.
Check the electrode for cracks or fissures before
cleaning it. Damaged components may not be used!
Clean the assembly using a dry (lint-free) or moist
cloth. Make sure that no fibres (bits of fluff) remain on
the electrode after cleaning.
Make sure not to use the device until the electrodes
have completely dried.
Remove any remaining dust or other built-up
of deposits, especially in the spaces between
the electrodes.
If it is required to remove the electrode, please pro-
ceed as follows:
Remove the fixing screws (2).
Remove the electrode (1) by slightly pulling
it out.
Clean the electrode as described above.
Insert the electrode back into place. Please be
aware that the electrode can be inserted in
one direction only. If it is not possible to insert
the electrode, rotate it by 180° and repeat the
procedure.
Operating manual – Airozon Supercracker
1
2
Caution!
Damage to the device due to
missing electrode!
Only operate the odour neutral-
iser with an inserted electrode.
EN