Emergency shut-down

If the ozone generator must be switched off during a
running cleaning cycle, this may not be done by ac-
tivating the power switch, i.e. at the device itself, for
reasons of safety.
In this case, the power plug located outside of the
treated room should be disconnected from the power
supply.
Warning!
Risk of injury due to ozone!
Do not enter a room to be cleaned
during a running cycle!

13. Care and maintenance

Note!
After maintenance, make sure
that the safety switch (1) inside
of the device is properly closed.
1
EN
In order to ensure a correct functioning and trouble-
free operation of the device, it must be regularly
cleaned and maintained.
The frequency and type of the maintenance work es-
sentially depends on the operating environment as
well as on how the odour neutraliser is used and for
what periods of time.
In the course of time, dust and moisture gather on the
assemblies which can impair the functioning and the
performance of the device.
In rooms with a high level of dust and contamination
or after post-fire restorations (high level of humid-
ity), you should already check if there is any need for
maintenance after only a few uses of the device.
Maintenance intervals can span several months in dry
environments such as hotels or within the scope of
car maintenance.

Criteria for determining the maintenance interval

The device is in operation:
often for many hours without interruption
on many days in any month
in heavily-polluted rooms
in moist rooms
Operating manual – Airozon Supercracker
Warning!
Risk of injury and damage to the
device!
Do not attempt to carry out any
unauthorised modiications on
the odour neutraliser.
Have all repairs carried out by
a certiied specialist workshop
only!
Danger!
Danger to life through electrical
shock!
Pull the power plug out of the
socket before carrying out any
work on the device.
Do not bypass any of the electri-
cal safety devices!