Operating Modes - Danby DAS120GAHWDB Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATING INSTRUCTIONS

OPERATING MODES

AUTO mode
• Press the mode button to select auto mode.
• The appliance will automatically select cooling,
heating or fan only operation depending on
what temperature has been set and the ambient
room temperature.
DRY
• Press the mode button to select the dry mode.
• Keep windows and doors closed for the best
dehumidifying effect.
• Condensed water will automatically drain
through the drain hose.
COOL / HEAT / FAN
• Press the mode button to select the desired
mode; cool, heat or fan.
• Press the temperature control buttons to select
your desired room temperature. The temperature
can be set within a range of 16°C - 32°C (61°F
- 90°F).
• Press the speed button to choose the fan speed.
AUTOMATIC FEATURES
Auto-Restart
If the appliance loses power, it will automatically
restart with the previous settings once power is
restored.
Louver Angle Memory
When turning on the appliance, the louver will
automatically resume the previous angle setting.
Refrigerant Leakage Detection
The indoor appliance will automatically display
"P3" when it detects a refrigerant leakage and the
appliance will shut off.
SLEEP
• The sleep feature is used to decrease energy use
during sleeping hours. This feature can only be
activated by pressing the sleep button on the
remote control.
• When in cool mode, the temperature will
increase by 1°C (2°F) in the fi rst hour and will
increase an additional 1°C (2°F) in the second
hour. The temperature will decrease by 1°C (2°F)
in 7 hour and another 1°C (2°F) in 10 hour.
• When in heat mode, the temperature will
decrease by 1°C (2°F) in the fi rst hour and will
decrease an additional 1°C (2°F) in the second
hour. The temperature will increase by 1°C (2°F)
in 7 hour and another 1°C (2°F) in 10 hour.
• At the end of sleep cycle, the appliance will
resume normal operation.
Note: The sleep feature is not available in fan and
dry mode.
ANTI-F
The Anti-F feature will run the fan at a very low
speed for 3 minutes to ensure that the interior of the
appliance is dry. This can prevent the formation of
odors inside the appliance.
Ensure the appliance is off. Press the Anti-F button
with the appliance turned off to activate this feature.
A buzzer will sound 10 times to indicate that Anti-F
is active. If the appliance is turned on during this
period, Anti-F will be deactivated.
To cancel the Anti-F feature, press the Anti-F button
while the unit is off but Anti-F is running. The unit
will sound 8 times to confi rm that Anti-F has been
turned off.
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Das170gahwdbDas220gahwdb

Table des Matières