In-Sight 8405 Vision System Specifications
Specifications
1
Case Temperature
Storage Temperature
Humidity
Protection
Shock (Shipping and
Storage)
Vibration (Shipping and
Storage)
1
Case temperature can be verified using the EV GetSystemConfig("Internal.Temperature") Extended Native Mode
command. When issued, it returns the vision system's internal temperature in degrees Celsius, which will be ±5
degrees above the vision system case temperature. Refer to the In-Sight
Additional cooling measures are required if the case temperature cannot be kept below 50°C. Examples of such
measures include: mounting the vision system to a heat sink using the M3 mounting screws, reducing the ambient
temperature and ensuring there is air flow over the vision system.
0°C to 50°C (32°F to 122°F)
-20°C to 80°C (-4°F to 176°F)
< 80% non-condensing
IP30 with cables and lens attached.
IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z) axis) 80 Gs
2
(800m/s
at 11ms, half-sinusoidal)
IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to
2
500 Hz at 100m/s
/ 15mm)
8405
®
Explorer Help file for more information.
15