3. Connect the trigger and high-speed I/O wires to an appropriate device (for
example, a PLC, trigger sensor or strobe light).
Option 2: Connect the I/O Module Cable
CAUTION:
A ferrite is included with the In-Sight 8405 vision system standard
components. To reduce emissions, the ferrite must be attached to the I/O
Module cable.
Note:
The CIO-MICRO I/O module supports In-Sight 8000 series vision
l
systems with firmware version 5.3.0 and higher.
I/O wiring or adjustments to I/O devices should be performed when
l
the vision system is not receiving power.
1. If installing the In-Sight 8405 vision system, attach the ferrite around the I/O
Module cable, adjacent to the strain relief on the cable.
2. Connect the I/O Module cable's M8 connector to the vision system's I/O
connector.
3. Connect the I/O Module cable's DB15 connector to the I/O module's I/O
connector.
4. Restore power to the 24VDC power supply and turn it on if necessary.