The lack of ventilation grilles in the envelope will generate a constant increase in the temperature that
cannot be used to heat the room and will fracture the envelope and the components of your Stove.
Fractures of the Stove's envelope and components due to excessive temperature and an absence of
vents are not covered under warranty.
Elbows always at 45º, but
not following the appliance
Thermal insulation panel
(rock wool + aluminum
film)
Outside air intake
d:80-100 mm
1.4. HOT AIR DISTRIBUTION
Your appliance is fitted with a heat recovery unit and two nozzles which allow the connection of flexible
tubes. Flexible tubes can be oriented to blow hot air to other rooms.
If you prefer the hot air to exit both through the nozzles and from the front, it is possible to remove the
deflectors. To access the deflectors, you must first remove the plug holes (fig. 6).
Overpressure grid
Air inlet around the appliance.
DO NOT FIX AND DO NOT SEAL
THE FRAME
Air inlet to the brick envelope
Fig. 3 – Example of installation to respect
Fig. 4
Filled with rock wool to block heat inside
the hood
Overpressure grid 25-30
cm from the ceiling
Optional convection air outlet
Does not replace the overpressure grille
Air inlet to lining for outlet and accumulation in
the hood
39