OPTIONAL PC-1 PRESET COUNTER SET-UP
• 1. For Auto-Stop, plug a Control Cable (with 3.5mm plugs at each end) between the External Halt Jack on the PC-1 and
the "EXTERNAL HALT CONTROL" Jack on the CAT-3 Label Rewinder.
• 2. The Counter is pre-programmed as a Count-Up Preset Counter. For other modes, refer to the Counter Data Sheet that
is part of the documentation package.
• 3. Successively press the Buttons below each digit to enter the desired count and then press the Red Reset/Enter But-
ton.
• 4. To reliably count your labels, it is recommended to calibrate the photocell whenever you are changing labels and/
or label material. The procedure is easy: position the backing paper in front of the photocell. Make sure that the labels
are tensioned when doing the calibration. The green LED (side of the counter) should light on. If not, rotate the potenti-
ometer (side of the counter) till LED goes on "green". Now put a label in front of the photocell, the LED should turn off.
• 5. Pull a short strip of labels back and forth through the Label Sensor Gap and observe the count on the Counter in-
creasing.
• 6. When the preset number of Labels is reached, the Counter will stop the S-100/S-200 and the External Halt Control
Relay will open, serving as a "Halt" Command for the CAT-3 Label Rewinder. Press the red Reset/Enter Button to reset
the count & restart the CAT-3.