Communication error
Fault
No time set on the charging
device.
Communication error with the
identification module (IM) when
connecting the battery.
Communication error with the
identification module (IM) during
the charging operation.
Communication error with
temperature sensor.
- 58 -
Electrically driven trolleys JLA-e 5/12 G, JLA-e 15/30 G and JLA-e 25/50 H
E9x Cause
• Incorrect time setting on the charging
E91
device or discharged storage battery
• IM is out of order, defective or not
E92
programmed
• Connection cable or plug defective
• IM is defective
E93
• Connection cable or plug is defective
• Defective temperature sensor
E94
• Connection cable or plug defective
Elimination
• Set correct time
• Check storage battery on the operating
module
• Connect, replace or program IM
• Check connection between IM and
charging device
• Replace IM
• Check connection between IM and
charging device
• Replace IM or temperature sensor
• Check the connection of the charging
device with the IM and temperature
sensor.